6
|
Sub-Zero Customer Care 800.222.7820
INTEGRATED REFRIGERATION
Electrical
The electrical supply must be located within the shaded
area shown in the illustration and chart below. A separate
circuit, servicing only this appliance is required. A ground
fault circuit interrupter (GFCI) is not recommended and may
cause interruption of operation.
The electrical outlet must be positioned with the grounding
prong to the right of the thinner blades.
Installation must comply with all applicable electrical codes.
ELECTRICAL REQUIREMENTS
Electrical Supply
115 VAC, 60 Hz
Service
15 amp
Receptacle
3-prong grounding-type
ELECTRICAL SUPPLY LOCATION
MODEL
A
IC-36FI
15
1
/
2
"
(394)
A
1
/
4
"
(6)
1
/
4
"
(6)
4
1
/
4
"
(108)
4
1
/
2
"
(114)
FLOOR
LEFT SIDE
OF OPENING
Electrical supply location.
Plumbing
The water supply line should be located within the shaded
area shown in the illustration below. The water supply line
should be connected to the house supply with an easily
accessible shut-off valve. Do not use self-piercing valves.
The water supply line must not interfere with installation of
the anti-tip bracket.
A reverse osmosis system can be used provided there is
constant water pressure of 35–120 psi
(2.4–8.3 bar)
supplied
to the unit at all times. A copper line is not recommended
for this application.
Installation must comply with all applicable plumbing codes.
PLUMBING REQUIREMENTS
Water Supply
1
/
4
" OD copper, braided
stainless steel or PEX tubing
Pressure
35–120 psi
(2.4–8.3 bar)
Excess Line for Connection
36"
(914)
WATER SUPPLY LOCATION
MODEL
A
IC-36FI
9"
(229)
3"
(76)
6"
(152)
RIGHT SIDE
OF OPENING
AREA EXTENDS 1
/
2
"
(13)
FORWARD ON FLOOR
A
Water supply location.