subzero.com | 5
Plumbing Requirements
Installation must comply with all applicable plumbing
codes.
The water supply line should be located within the shaded
area shown in the illustration below. The water supply line
should be connected to the house supply with an easily
accessible shut-off valve. Do not use self-piercing valves.
The water supply line must not interfere with installation of
the anti-tip bracket.
A reverse osmosis system can be used provided there is
constant water pressure of 2.4–8.3 bar supplied to the
unit at all times. A copper line is not recommended for this
application.
PLUMBING REQUIREMENTS
Water Supply
6.4 mm OD copper, braided
stainless steel or PEX tubing
Pressure
2.4–8.3 bar
(240–830 kPa)
Excess Line for Connection
.9 m
Electrical Requirements
Installation must comply with all applicable electrical
codes and be properly grounded (earthed).
The electrical supply should be located within the shaded
area shown in the illustration below. A separate circuit
servicing only this appliance is required.
IMPORTANT NOTE:
A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
ELECTRICAL REQUIREMENTS
Electrical Supply
220-240 V AC, 50/60 Hz
Service
10 amp
Receptacle
grounding-type (earthed)
Site Preparation
Dual Installation
If two units are installed side by side, a dual installation kit
may be required. Installations without a custom filler strip
require a dual installation kit. If a dual installation kit is not
specified, a 51 mm filler strip is recommended between
units. Dual installations without a filler strip can only be
accomplished using two units with opposite hinges. Refer
to the illustrations below.
Dual installation kits are available through an authorized
Sub-Zero dealer. For questions regarding the installation,
contact your authorized Sub-Zero dealer.
WITHOUT FILLER STRIP
FILLER STRIP
Opposite hinges
Same side hinges
76 mm
457 mm
152
mm
RIGHT SIDE
OF OPENING
AREA EXTENDS
13 mm
FORWARD ON FLOOR
Water supply location
1918 mm
FROM FLOOR
178
mm
E
152
mm
RIGHT SIDE
OF OPENING
Electrical supply location
CAUTION
The outlet must be checked by a qualified electrician
to be sure it is wired with the correct polarity. Verify
the outlet is properly grounded (earthed).
WARNING
If the supply cord is damaged, it must be replaced
with a special cord or assembly available from the
manufacturer or its service agent.
WARNING
Do not locate multiple portable socket-outlets,
power strip, or portable power supplies at the rear of
the appliance.
WARNING
Do not use an extension cord, two-prong adapter, or
remove the power cord ground prong.
Electrical
Shock
Hazard
Plug power cord directly into a properly
grounded (earthed) outlet.
Do not defeat the grounding (earthing)
nature of the plug.
Do not use adapter or extension cord.
Failure to follow these instructions could
cause serious injury or death.
See installation instructions