background image

RS-232

Windows 95/98/NT/2000/XP/2003 Server

SU600WB

600VA/12V

MODEL

CAPACITY

INPUT PARAMETERS 

OUTPUT PARAMETERS (MAINS MODE) 

OUTPUT PARAMETERS (INVERTER MODE) 

BATTERY PARAMETERS 

USER INTERFACE

PROTECTION

Communication Port

Over/Under Voltage

Overload/Short Ckt

Low/High Battery

Surge Protection

Operating System

Voltage Regulation    

200VAC-245VAC

50 ±

 

0.2Hz

Sine Wave

8 msec

105% for 3 mins, 160% for 5 secs

Frequency Regulation    

Output Waveform

Transfer Time (Typical)

Overload Handling Capacity

Input Supply    

Voltage range 

Frequency Range    

1 Phase, 3 Wire

145VAC-295VAC ±

 

5V

200VAC-255VAC ±

 

5V

Waveform

Voltage range 

Frequency Range    

Same as Input

Same as Input

Same as Input

12V

1 ±

 

0.1A

Cell / Battery Type

Battery Voltage (Nominal)

Battery Charging Current

12V/7.2AH   

Switch to battery O/P when mains is over/under 
                        the specified range

  Battery deep discharge / over charge protected

Yes

Fuse & current limited for battery mode,          
     Fuse protection for mains mode

5.   Technical Specifications

5.   Technical Specifications

REV. 05-02-08

Info Disc
Manager

(9)

Technical

Specifications

(11)

Note : Specifications subject to change without prior notice.

Sine Wave LI UPS 

Содержание SU600WB

Страница 1: ...ion Cold start at full load Software controlled double protection for Overload and short circuit RS 232 interface for auto shutdown PURE SINE WAVE LI UPS 600VA 600VA GLOBAL CERTIFICATIONS GLOBAL CERTI...

Страница 2: ...6 2 3 Storage Instructions 6 3 Communication Interface 3 1 DB9 Communication Port 7 3 2 UPS Monitoring Software 8 9 Info Disc Manager 4 Trouble Shooting 10 5 Technical Specifications 5 1 Sine Wave LI...

Страница 3: ...utility line failures disturbances frequency deviations spikes and surges In the event of utility power failure the UPS will rapidly transfer loads to an alternative power source which derives power f...

Страница 4: ...ry overload short circuit protection and also in case of no load shut down There will be no LED indication in such a case 1 2 Panel s Explanation 1 3 LED Indications Front Panel Back Panel SINE WAVE L...

Страница 5: ...er Please observe the following precautions Do not disassemble the UPS Connect the UPS to a two pole three wire Line Neutral Earth mains with receptacle Connection with any other type of receptacle ma...

Страница 6: ...he Carton Box for any damage that may have occurred while in transit Immediately notify the carrier and place of purchase if there is any damage Retain the package for future use Connect the power cor...

Страница 7: ...the power Cord To test backup function during power failure press the front power switch for few seconds The UPS will work in backup mode with buzzer beeps In this mode the LED glows continuously in R...

Страница 8: ...communication between the UPS and Computer interface kit required The diagrammatic interface communication cable of UPS with computer REV 05 02 08 COMMUNICATION CABLE 1 6 7 8 1 2 3 4 6 7 8 2 3 4 1 1...

Страница 9: ...with the UPS The port once selected will become the default and the software will start automatically on that port every time In case user wants to change the port which is once made default then he m...

Страница 10: ...ailure status indicator Low battery status indicator UPS power status last three log records This is a complete solution designed to prevent hard disk crashes and to take care of sophisticated compute...

Страница 11: ...ooting 4 Trouble Shooting Possible Cause Problem Trouble Shooting No light No Alarm switch 1 AC fuse Blown Replace AC fuse of actual rating Turn On mains switch Contact your dealer Reduce Load Check l...

Страница 12: ...oad Handling Capacity Input Supply Voltage range Frequency Range 1 Phase 3 Wire 145VAC 295VAC 5V 200VAC 255VAC 5V Waveform Voltage range Frequency Range Same as Input Same as Input Same as Input 12V 1...

Страница 13: ...SU600WB 600VA 12V MODEL CAPACITY ENVIRONMENTAL PARAMETERS OTHERS Protection Class Dimensions W X D X H in mm Weights Kg LED Indications Alarm IP20 6 5 112 x 345 x 150 Indications Alarm Acoustic Noise...

Страница 14: ...Model No Serial No Name of Purchaser Address Date of Purchase Dealer s Name DEALER STAMP REV 05 02 08 13 Warranty Sine Wave LI UPS...

Страница 15: ...r unauthorized repairs done or carried out will have to be borne by the purchaser The problem of fuse blown will not be included in the warranty of the product The services given for the same will be...

Страница 16: ...kam com DELHI 940 2nd Floor Synagogue Street Near Railway Reservation Centre Camp Pune 1 Maharashtra Tel 020 32303900 30523788 09975496268 Email pune su kam com PUNE 74 D Plot No 1 Park Road 3 Ashok...

Отзывы: