Style selections SSEB18RT Скачать руководство пользователя страница 22

22

Provided Logs: 10

24 IN. VENT-FREE GAS LOGS and 30 IN. VENT-FREE GAS LOGS

INSTALLING LOGS

 

WARNING:

 Failure to position the parts in accordance with these diagrams or failure to use 

      only parts specifically approved with this heater may result in property damage or personal 

      injury.

 

CAUTION: 

After installation and periodically thereafter, check to ensure that no yellow flame 

      comes in contact with any log. With the heater set to High, check to see if yellow flames 

      contact any log. If so, reposition logs according to the log installation instructions in this manual. 

      Yellow flames contacting logs will create soot.

      It is very important to install the logs exactly as 

      instructed. Do not modify logs. Use only logs 

      supplied with heater. 

      Each log is marked with a number. This 

      number will help you to identify the logs 

      when installing. 

      After installing logs, add decorative cinders 

      around the grate base, do not place any 

      decorative cinders on logs or burner.

1.  Insert log #1 in pin on the left 

of the burner,Insert log #2 in 

pin on the right of the burner.

9.  Put log #10 in the front of floor 

near the burner.

3.  Insert log #4 into slots in rear 

log bracket on grate base.

2.  Insert log #3 into slots in rear 

log bracket on grate base. 

6.    Insert  the  recessed  hole  on  the 

bottom of log #7 onto pin on log 4# , 
with the other end placed 

on grate 

base

.

5.  Insert the recessed hole on the 

bottom of log #6 onto pin on log 
4# , with the other end placed 

on 

grate base

.

4. Insert the recessed hole on the 

bottom of log #5 onto pin on log 
4# , with the other end placed 
on grate base.

7.  Insert the recessed hole on the 

bottom of log #8 onto pin on log 
3# .

8. 

Insert log #9 into slots in rear 

log bracket on grate base

 .

Содержание SSEB18RT

Страница 1: ...ohibited by local codes This appliance is for use with the type of gas indicated on the rating plate only This appliance is not convertible for use with other gases This is an unvented gas fired heate...

Страница 2: ...ONS ITEM 0110999 Input Rating 25 000 BTU Hr 25 000 BTU Hr Gas Type Natural LP Propane Ignition Electronic Piezo Electronic Piezo Manifold Pressure 4 in W C 9 in W C Inlet Gas Pressure For purposes of...

Страница 3: ...are odorless An odor making agent is added to the gas The odor helps you detect a gas leak However the odor added to the gas can fade Gas may be present even though no odor exists Make certain you rea...

Страница 4: ...lways operate heater with glass doors fully open 6 This log heater is designed to be smokeless If logs ever appear to be smoking turn off heater and call a qualified service technician Note During ini...

Страница 5: ...s familiar with all precautions required and that has complied with all the requirement of the authority having jurisdiction 12 Do not use heater if any part has been underwater Immediately call a qua...

Страница 6: ...a copy of 527 CMR 30 upon sale of the unit In the State of Massachusetts unvented propane or natural gas fired space heaters shall be prohibited in bedrooms and bathrooms In the State of Massachusetts...

Страница 7: ...ore beginning assembly or operation of the product make sure all parts are present Compare parts with package contents list If any part is missing or damaged do not attempt to assemble install or oper...

Страница 8: ...gate input rating of all appliances installed in that space Rooms connecting directly with the space in which the appliances are installed through openings not furnished with doors are considered a pa...

Страница 9: ...as heater logs __________BTU hr Gas water heater 30 000 BTU hr Other gas appliances ____BTU hr Vent free heater 26 000 BTU hr Total ____BTU hr Total 56 000 BTU hr Do not include direct vent gas applia...

Страница 10: ...two spaces see options 1 and 2 Fig 1 You can also remove door into adjoining room see option 3 Fig 1 Follow the National Fuel Gas Code NFPA 54 ANS Z223 1 Air for Combustion and Ventilation for requir...

Страница 11: ...may cause mildew to form from too much moisture See Air for Combustion and Ventilation pages 8 through 10 WARNING Before installing in a solid flue burning firebox the chimney flue and firebox must be...

Страница 12: ...oncombustible Material Clearance If Not Using Mantel You must have noncombustible material s above the fireplace opening Noncombustible materials such as slate marble tile etc must be at least 1 2 in...

Страница 13: ...between mantel shelf and top of fireplace opening a hood is not necessary see Fig 5 Noncombustible Material Distance Requirements for Safe Installation 8 in or more Noncombustible material okay Less...

Страница 14: ...the flue damper open only Raise the mantel to an acceptable height FLOOR CLEARANCES a If installing appliance on floor level you must maintain the minimum distance of 14 in to combustibles see Fig 7...

Страница 15: ...nt free operation 3 You prefer vented operation If reasons number 1 or 2 above apply to you you must permanently open chimney flue damp er You must install the damper clamp accessory provided This wil...

Страница 16: ...b clockwise until the knob locks into the NG position see Fig 11 3 Remove steel or metal hex plug with wrench provided from natural gas inlet of regulator and install into LP inlet of regulator use th...

Страница 17: ...e Apply pipe joint sealant lightly to male threads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged heater valves CAUTION Use only a new black iron...

Страница 18: ...hreads Connect approved flexible gas hose to gas regulator of heater see Fig 13 Note Never apply pipe sealant to flare fitting threads 2 Locate masonry screws in hardware package 3 Position heater bas...

Страница 19: ...eaks immediately 6 Reconnect heater and equipment shutoff valve to gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve...

Страница 20: ...ted to receiver and AF 1110 valve See Fig 21 3 With receiver wired to the valve place receiver to the side of the log set See Fig 22 Fig 20 Fig 21 Black Wire Red Wire PLACING EMBER MATERIAL Seperate t...

Страница 21: ...ed with a number This number will help you to identify the logs when installing After installing logs add decorative cinders around the grate base do not place any decorative cinders on logs or burner...

Страница 22: ...og is marked with a number This number will help you to identify the logs when installing After installing logs add decorative cinders around the grate base do not place any decorative cinders on logs...

Страница 23: ...is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately cal...

Страница 24: ...seconds Note The first time the heater is operated after connecting the gas supply the control knob should be depressed for about thirty 30 seconds This will allow gas to bleed from the gas system 9...

Страница 25: ...ned by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separ...

Страница 26: ...r at the same time this will change from F to C Follow this same procedure to change from C back to F MANUAL FUNCTION To operate the system in the manual MODE do the following ON OPERATION Press the O...

Страница 27: ...rature for 3 seconds then the LCD screen will default to display the room temperature 3 Press the MODE key to disengage the thermo mode The word ROOM on the LCD screen will not show when the thermo is...

Страница 28: ...ame Pattern with Control Knob Set to High Flame 5 Fig 36 Incorrect Pilot Flame Pattern with Control Knob Set to High Flame 5 BURNER FLAME PATTERN Fig 35 shows a correct burner flame pattern Fig 36 sho...

Страница 29: ...eps 3 and 4 Clean the pilot assembly also WARNING Failure to keep primary air openings of burners clean may result in sooting and property damage CAUTION You must keep control areas burner and circula...

Страница 30: ...r inlet hole You may blow through a drinking straw if compressed air is not available CABINET Air Passageways Use a vacuum cleaner or pressurized air to clean the cabinet to remove dust t Exterior Use...

Страница 31: ...nitor electrode is broken 3 Ignitor electrode is not connected to ignitor cable 4 Ignitor cable is pinched or wet 5 Damaged ignitor cable 6 Bad piezo ignitor 7 Low battery 1 Replace electrode 2 Replac...

Страница 32: ...o not attempt to fix Burner s does not light afterODS pilot is lit 1 Burner orifice is clogged 2 Burner orifice diameter is too small 3 Inlet gas pressure is too low 1 Burner orifice see Care and Main...

Страница 33: ...duces unwanted odors 1 Heater is burning vapors from paint hair spray glues etc See IMPORTANT statement page 31 2 Gas leak See Warning Statement at the top of page 31 3 Low fuel supply 1 Ventilate roo...

Страница 34: ...Customer Service have ready Your name Your address Model and serial number of your heater How heater was malfunctioning Type of gas used Propane LP or Natural gas NG Purchase date Usually we will ask...

Страница 35: ...embly FBB28D11 1 6 Selector Valve YDF06 1 7 Knob MDL304B 1 8 Selector Valve Bracket SSEB30RT009 1 9 Remote control valve AF 1110 1 10 Receiver box UN3 1 11 Receiver Box Housing RS 1A 1 12 Remote contr...

Страница 36: ...36 0110999 SSEB18RT...

Страница 37: ...e control valve AF 1110 AF 1110 1 10 Receiver box UN3 UN3 1 11 Receiver Box Housing RS 1A RS 1A 1 12 Remote control CON1001TH CON1001TH 1 13 Rear Log Bracket SSEB30RT016 SSEB30RT016 1 14 Log 1 SSEB30R...

Страница 38: ...38 0112970 0114757 SSEB24RT SSEB30RT...

Страница 39: ...ccident misuse improper installation or by affixing accessories not produced by the manufacturer are the purchaser s responsibility The manufacturer assumes no responsibility whatsoever for installati...

Отзывы: