STV Electronic MPW16 Series Скачать руководство пользователя страница 3

Instruc on Manual - Level converter series MPW16-serial

Technical Data

MPW16-RS-232

MPW16-RS-485

Art.No.

95560

95561

Supply voltage. DC

24V ±20%

Supply voltage. AC

24V ±5%

Self-consump on

85 mA at 24Vdc

Ingress protec on

IP 20

Opera ng 

temperature

0 … 50°C

Rela ve humidity

0 … 90% (without condensa on)

M-Bus voltage

37 V

M-Bus current

MPW16: 24 mA (16 standard loads @ 1,5 mA)

Over current 

threshold

M-Bus current >30 mA

Galvanic isola on

Between supply voltage, RS-232 / RS-485 and M-Bus

Collision detec on

yes

Data rate M-Bus

300 … 38400 Baud

Interfaces

1 x RS-232

1 x RS-485

Measurements 

(WxLxH)

52,5 x 90 x 64 mm

(3HP)

Moun ng

On moun ng rail TS35 or with screw lugs

Weight

approx. 135 g

Displays

Data: Tx/Rx two-coloured (yellow, green)

Power: supply voltage (green)

Overload: M-Bus over current (red)

Bu on

Service: Set factory se ngs, press and hold for 30 s un l the

power LED flashes.

Moun ng

Moun ng on moun ng rail

The level converters can be mounted on commercially available moun ng rails of type TS35 
by snapping them on. A single level converter takes up a width of 52.5 mm (3HP).

Moun ng with screw lugs

To a ach the level converters with screw lugs, the black lugs on the back of the housing 
must be pushed outwards un l they snap into place.

When engaged, the level converter can be screwed on with two M4 screws (top and 
bo om).

V01.0612.01_en

STV Electronic GmbH

Hellweg 203 – 205

33758 Schloss Holte

Отзывы: