Other Icons
There is a battery icon in the upper right-hand quadrant of the screen above the units of measure. This icon 
and other indications are used to warn the user when the battery voltage drops to a level where the batter-
ies should be replaced.

There are two icons used in normal operating mode (during performance of a task) to provide a quality at-
tribute indication for a just-completed fastener. The “OK” and “BAD” icons are located along the bottom of 
the display on the left side. When a torque application is completed and the fi nal torque result is compared 
to the torque specifi cation values for the task, an attribute evaluation is made and the appropriate icon is 
illuminated briefl y.

Definitions
Target

 

A specific torque value: the midpoint between the minimum and maximum torque specifi-
cation values for the task.

Peak

 

Mode of operation capturing the highest torque value in a single loading of the wrench.

Residual

 

Mode of operation for capturing the torque remaining on a previously-installed fastener. In 
this mode the tool captures the lowest point between two peaks; the peak torque to begin 
fastener motion (includes inertia) and the peak torque where force application stopped. 

Stored

 

Mode of operation used to review torque values currently stored on the tool.

Task

 

A set of from 1 - 50 torque applications grouped together and sharing common unit of 
measure and torque value specification. Tasks are numbered from “00” to “50”.

Record

 

A single torque application within a specific Task. Numbered from “00” to 50. Record 00 is  
designed to give the user the ability to use the specifications for the active task on a 
fastener without recording the result.

UOM

 

Currently active Unit of Measure for torque. IN.LB, FT.LB, Nm

Clear Button

 

Clear the current reading from the display and, if in a task or record other than “00”, begin 
storing information at the current point.

Select Button

 

Used to enter, select, and exit various options on the tool itself.

Up Button

 

Used to move (increment) upwards among options and increment levels within a selected 
option.

Down Button

 

Used to move (decrement) downwards among options and increment levels within a 
selected option.

Task 00

 

A special task always available, even when specific tasks have been downloaded to the 
tool. When Task 00 is displayed, the tool functions as a torque wrench with no memory of 
the torques applied, similar to a beam or dial wrench. When there is no job on the tool, 
the default settings for the tool will be applied.

Yellow Light

 

Color (orange- yellow) projected onto display to indicate that the warning torque level has 
been reached during use and that the speed of force application should be slowed. Use 
of the LED color scheme is selectable in the software (active or inactive). Warns user that 
the torque specification is being approached. Used in all Tasks numbered 01 and above 
when record 01 and above are active. Not available in “Task 00” or “Record 00”.

Green Light

 

Color projected onto display to indicate that the current torque is within the limits of the 
minimum and maximum torque specified for that Task. Use of the LED color scheme is 
selectable in the software (active or inactive). Active in all Tasks numbered greater than 
“00”. Not available in “Task 00” or “Record 00”.

Содержание exacta 2 3000 series

Страница 1: ...nd Battery Chargers These tools were designed to use only and solely NiMH batteries having specific dimensions and operating characteristics Within NAFTA countries the only batteries that are to be us...

Страница 2: ...At that time the display will show the message bAtt and the ability to operate the wrench will be lost Readings stored prior to that point will remain in memory The tool will remain inoperable until...

Страница 3: ...tion here due to differences in the fonts used Target When the triangular icon beneath this is illuminated it means that the target value for the torque specification is displayed in the main section...

Страница 4: ...specific Task Numbered from 00 to 50 Record 00 is designed to give the user the ability to use the specifications for the active task on a fastener without recording the result UOM Currently active Un...

Страница 5: ...ted Up Navigate among tasks and records Increments count of displayed task or record by one Down Navigate among tasks and records Decrements count of displayed task or record by one Display During Ope...

Страница 6: ...the Exacta Plus software is being used to communicate with it avoid touching the buttons on the tool and do not disable the power Allow the software to perform the communications and complete them bef...

Страница 7: ...records for that task have been obtained Once the last fastener in a task has been completed the information will be displayed normally then the screen will display SEt in the main section Use the Up...

Страница 8: ...but the use of a mechanical loader is still recommended The load applied during testing must be at the loading point on the grip indicated by the plain ring at the middle of the grip It is imperative...

Страница 9: ...diagnostic D Command into the terminal and press enter The Terminal display will dis play DiaOn You are now in diagnostic mode 8 Type the M enter The capacity of the tool should be seen on the displa...

Страница 10: ...ress the DOWN arrow key Unload the tool 6 Press the Up arrow key until 70 appears in the lower right corner of the LCD display Apply 70 CW FS load to the unit When exactly 70 CW FS torque is applied p...

Страница 11: ...load to the unit When exactly 60 CCW FS torque is applied press the DOWN arrow key Unload the tool 20 Press the Up arrow key until 50 appears in the lower right corner of the LCD display Apply 50 CCW...

Страница 12: ...300 303 297 75 foot pounds Capacity in Ft Lb FS Torque Value in In Lb Tol Tol 75 10 90 90 9 89 1 20 180 181 8 178 2 30 270 272 7 267 3 40 360 363 6 356 4 50 450 454 5 445 5 60 540 545 4 534 6 70 630...

Страница 13: ...4 30 1440 1454 4 1425 6 40 1920 1939 2 1900 8 50 2400 2424 2376 60 2880 2908 8 2851 2 70 3360 3393 6 3326 4 80 3840 3878 4 3801 6 90 4320 4363 2 4276 8 100 4800 4848 4752 600 foot pounds Capacity in F...

Страница 14: ...to the sensor including damage of a level that necessitates replacement We strongly recommend that the tool never be used beyond its rated capacity and that if the tool is inadvertently overloaded it...