background image

Sturtevant Richmont

 -  P/N 857285 - Issue Date 100407 - Page 1 of 14

Sturtevant Richmont

Global Reach.  Local Support.

Division of Ryeson Corporation

3203 N. Wolf Road

Franklin Park, IL   60131

Phone: 847/455-8677  800/877-1347

Fax: 847/455-0347

Website: www.srtorque.com

E-mail: [email protected]

Operating and Service Manual

3000-Series 

Exacta

® 

2

 Digital Torque Wrenches (All Models)

The 3000-Series 

Exacta

®

 

2

 Digital Torque Wrenches are designed for use in applications where accuracy, 

control and recording of the torque data are of high importance. They are the electromechanical tool portion 
of an integrated system that includes Exacta Plus software from Sturtevant Richmont.

Safety

• 

Always wear appropriate safety equipment when using this or any other hand tool.

• 

Never use the tool for other than its designed purpose.

• 

Never use the tool outside of its rated capacity.

Batteries and Battery Chargers

These tools were designed to use only and solely NiMH batteries having specifi c dimensions and operating 
characteristics. Within NAFTA countries, the only batteries that are to be used with 3000-Series 

Exacta

®

 

2

 

digital torque wrenches are those immediately below.

 P/N 

Model 

Description

21259 

Charger & 4 AA 

NiMH  4 AA NiMH 2200 mAh batteries & charger, NAFTA only 

21258 

4 AA NiMH 

Batteries 2500 mAh NiMH batteries, spare

Battery Caution!

• 

Use of any other NiMH batteries may cause inaccurate torque readings.

• 

Use of any other NiMH batteries may damage the tool and may void the warranty.

• 

Use of any Alkaline battery 

will

 damage the tool and 

will

 void the warranty.

In countries outside of NAFTA, go to the S/R website page given below to select the correct batteries for 
use with the 3000-Series 

Exacta

®

 

2

 digital torque wrenches. The same cautions listed above apply to all of 

the 3000-Series 

Exacta

®

 

2

 digital torque wrenches, regardless of the country in which the tool is purchased 

and used. The URL for the needed information is:

http://www.srtorque.com/batteries.html

Содержание exacta 2 3000 series

Страница 1: ...nd Battery Chargers These tools were designed to use only and solely NiMH batteries having specific dimensions and operating characteristics Within NAFTA countries the only batteries that are to be us...

Страница 2: ...At that time the display will show the message bAtt and the ability to operate the wrench will be lost Readings stored prior to that point will remain in memory The tool will remain inoperable until...

Страница 3: ...tion here due to differences in the fonts used Target When the triangular icon beneath this is illuminated it means that the target value for the torque specification is displayed in the main section...

Страница 4: ...specific Task Numbered from 00 to 50 Record 00 is designed to give the user the ability to use the specifications for the active task on a fastener without recording the result UOM Currently active Un...

Страница 5: ...ted Up Navigate among tasks and records Increments count of displayed task or record by one Down Navigate among tasks and records Decrements count of displayed task or record by one Display During Ope...

Страница 6: ...the Exacta Plus software is being used to communicate with it avoid touching the buttons on the tool and do not disable the power Allow the software to perform the communications and complete them bef...

Страница 7: ...records for that task have been obtained Once the last fastener in a task has been completed the information will be displayed normally then the screen will display SEt in the main section Use the Up...

Страница 8: ...but the use of a mechanical loader is still recommended The load applied during testing must be at the loading point on the grip indicated by the plain ring at the middle of the grip It is imperative...

Страница 9: ...diagnostic D Command into the terminal and press enter The Terminal display will dis play DiaOn You are now in diagnostic mode 8 Type the M enter The capacity of the tool should be seen on the displa...

Страница 10: ...ress the DOWN arrow key Unload the tool 6 Press the Up arrow key until 70 appears in the lower right corner of the LCD display Apply 70 CW FS load to the unit When exactly 70 CW FS torque is applied p...

Страница 11: ...load to the unit When exactly 60 CCW FS torque is applied press the DOWN arrow key Unload the tool 20 Press the Up arrow key until 50 appears in the lower right corner of the LCD display Apply 50 CCW...

Страница 12: ...300 303 297 75 foot pounds Capacity in Ft Lb FS Torque Value in In Lb Tol Tol 75 10 90 90 9 89 1 20 180 181 8 178 2 30 270 272 7 267 3 40 360 363 6 356 4 50 450 454 5 445 5 60 540 545 4 534 6 70 630...

Страница 13: ...4 30 1440 1454 4 1425 6 40 1920 1939 2 1900 8 50 2400 2424 2376 60 2880 2908 8 2851 2 70 3360 3393 6 3326 4 80 3840 3878 4 3801 6 90 4320 4363 2 4276 8 100 4800 4848 4752 600 foot pounds Capacity in F...

Страница 14: ...to the sensor including damage of a level that necessitates replacement We strongly recommend that the tool never be used beyond its rated capacity and that if the tool is inadvertently overloaded it...