Studio Technologies 46A Скачать руководство пользователя страница 5

Model 46A User Guide 

Issue 1, September 2014 

Studio Technologies, Inc. 

Page 5

Introduction

The Model 46A is designed to interface  

2-wire full-duplex party-line (PL) intercom 

circuits with 4-wire audio circuits associ-

ated with matrix intercom systems. Other 

specialized audio system interfacing appli-

cations can also be supported. The Model 

46A provides two independent full-fea-

tured 2-channel interfaces. Each interface 

contains two hybrid circuits which include 

automatic nulling capability. The analog 

circuitry, under software control, provides 

excellent audio quality and high return-loss. 

The interfaces are compatible with powered 

and unpowered 2-wire party-line circuits. 

They are capable of supplying DC power, 

allowing direct operation of devices such as 

user beltpacks. Configuration settings al-

low the 2-wire and 4-wire interface circuitry 

to be compatible with a range of nominal 

signal levels. Audio level meters provide 

user confirmation of system performance 

during setup and operation. Applications for 

the Model 46A include television sports and 

special event broadcasting, theme park and 

theater installations, corporate events, and 

industrial testing environments. Standard 

audio connectors are used for all input and 

output signals. The Model 46A mounts in 

Model 46A Back Panel

Model 46A Front Panel

one space of a standard 19-inch rack  

enclosure and requires 100-240 volts, 

50/60 Hz for operation.

2-Wire Interfaces

The Model 46A’s 2-wire interfaces are  

optimized for direct connection with  

2-channel party-line intercom circuits.  

In addition, single-channel party-line 

intercom circuits can also be connected. 

Many broadcast applications use the 

2-channel TW-Series from RTS®, includ-

ing their popular BP-325 beltpack. Other 

industry-standard single- and 2-channel 

PL intercom systems, including those from 

Clear-Com®, are also directly compatible. 

To provide optimal signal matching and 

interface performance the nominal level of 

the Model 46A’s 2-wire interfaces can be 

selected. Using DIP switches, accessible 

on the front panel, the nominal levels can 

be selected to be either –10 or –14 dBu, 

settings that should allow compatibility 

with virtually all party-line systems. For ex-

ample, for applications that use equipment 

from RTS the –10 dBu setting is appropri-

ate. For other equipment, such as that 

from Clear-Com, the –14 setting is correct.
The Model 46A’s 2-wire interfaces can  

correctly function with powered (“wet”)  

or unpowered (“dry”) intercom circuits.  

Содержание 46A

Страница 1: ...pyright 2014 by Studio Technologies Inc all rights reserved www studio tech com 50115 0914 Issue 1 User Guide Issue 1 September 2014 This User Guide is applicable for serial numbers M46A 01151 and lat...

Страница 2: ...This page intentionally left blank...

Страница 3: ...10 Con guration 16 Advanced Con guration 17 Operation 20 Advanced Operation 24 Technical Notes 25 Speci cations 27 Appendix A Interfacing with RTS Matrix Intercom Systems 28 Appendix B Interfacing wit...

Страница 4: ...Issue 1 September 2014 Model 46A User Guide Page 4 Studio Technologies Inc This page intentionally left blank...

Страница 5: ...rate events and industrial testing environments Standard audio connectors are used for all input and output signals The Model 46A mounts in Model 46A Back Panel Model 46A Front Panel one space of a st...

Страница 6: ...rted Each interface s 30 volt DC intercom power source ensures that systems requiring long intercom cable runs will function correctly The circuitry s output regulation is such that little change in t...

Страница 7: ...disabling open microphones the auto nulling process can achieve better performance 4 Wire Interfaces Associated with the 4 wire portion of the Model 46A s interfaces are analog line level inputs and o...

Страница 8: ...ircuitry that under software control applies 200 ohm terminating impedances to the 2 wire party line circuits This along with other circuitry that monitors DC voltages pres ent on the 2 wire circuits...

Страница 9: ...del 46A s design process conversa tions with industry experts quickly made it apparent that installing and con guring existing 2 wire to 4 wire interface units was invariably a time consuming aggravat...

Страница 10: ...e an AC mains cord Your dealer or distributor should provide an AC mains cord for other destinations Locating the Model 46A The Model 46A s mounting location will dictate the length of the cable runs...

Страница 11: ...les so that pin 2 is signal high or hot pin 3 is low or cold and pin 1 is shield If connecting a source in this manner results in hum or noise it s possible that removing the shield connection from pi...

Страница 12: ...cted appropriately For convenience the 2 wire PL intercom circuits can be connected to the Model 46A by way of four 3 pin male XLR connectors two are located on the back panel and two on the front The...

Страница 13: ...functions auto nulling for interface 1 auto nulling for interface 2 and a special mic kill function Remote con trol of the auto nulling functions provides a resource identical to that of the front pan...

Страница 14: ...tter yet be terminated onto another connector such as a 9 pin D subminiature type There are several ways of preparing to connect to the remote control inputs The easiest means is to purchase an interc...

Страница 15: ...er of 100 to 240 V 50 60 Hz As a universal mains input device there are no switches to set or jumpers to install A 3 pin IEC 320 C14 inlet connector on the Model 46A mates with a detachable mains cord...

Страница 16: ...intercom channels Two 3 pin male XLR connectors one located on the Model 46A s front panel and one on the back panel are used to intercon nect the Model 46A with the intercom user devices When switch...

Страница 17: ...from Riedel The 8 dBu setting is provided speci cally when interconnecting the Model 46A with audio signals associ ated with an RTS ADAM Series of matrix intercom system This includes the related RVO...

Страница 18: ...terminate function is ac tive When switch 1 is in its on up posi tion the auto terminate function associated with each interface is disabled Repeating for clarity the auto terminate function ap plies...

Страница 19: ...e for applications in which the two audio paths associated with each interface are used with independent party line intercom circuits This situation might arise when two Clear Com single channel inter...

Страница 20: ...with the approximate level of 4 dBu is present on the associated 4 wire output connector Another example would be a Model 46A interface con gured for 8 dBu operation and 18 and 12 dB LEDs are lit This...

Страница 21: ...io level Con rm that the DIP switch associated with each interface is set to match the nominal level of the con nected devices RTS user devices have a nominal level of 10 dBu Clear Com devic es typica...

Страница 22: ...to use RTS BP 325 beltpacks Select the con nected devices so that their total current doesn t exceed 315 mA That s not always the easiest gure to calculate but a web search will generally nd speci ca...

Страница 23: ...ctive An actual auto null sequence starts by muting the 4 wire input and output signal paths associated with the speci c channel to be nulled Then a short period of 24 kHz signal is sent out the 2 wir...

Страница 24: ...clean As a visual aid LEDs on the front panel will display the DC power status of pins 2 and 3 But when auto terminate is not active the LEDs will no longer indicate the intercom circuit s terminatio...

Страница 25: ...oftware Version Display A special Model 46A power up sequence allows the unit s software version number to be displayed This is useful when work ing with factory personnel on application support and t...

Страница 26: ...ity Not a TW 12B Replacement The Model 46A will provide a high level of performance over its range of intended tasks But it s not intended to act as a universal 2 wire to 2 wire interface such as is p...

Страница 27: ...apacitive 2 wire party line loads Nulling Method automatic upon user initiation processor implements digital control of analog cir cuitry null settings stored in non volatile memory Nulling Line Imped...

Страница 28: ...ser Guide Page 28 Studio Technologies Inc Interfacing RTS Matrix Intercom Systems with the Model 46A Interface Appendix A ADAM Matrix Intercom System Analog Ports to Model 46A Interface RVON I O I O C...

Страница 29: ...Model 46A User Guide Issue 1 September 2014 Studio Technologies Inc Page 29 Interfacing Riedel Artist Matrix Intercom System Analog Ports with the Model 46A Interface Appendix B...

Страница 30: ...Issue 1 September 2014 Model 46A User Guide Page 30 Studio Technologies Inc Interfacing Clear Com Matrix Intercom System Analog Ports with the Model 46A Interface Appendix C...

Страница 31: ......

Страница 32: ......

Страница 33: ......

Отзывы: