SAFETY INFORMATION (service personnel)

IMPORTANT !

READ ALL CAUTIONS AND WARNINGS PRIOR TO OPERATE THIS EQUIPMENT.
INSTRUCTION TO PREVENT INJURY OR DAMAGE DUE TO ELECTRIC SHOCK, FIRE, MECHANICAL HAZARDS, DANGEROUS MATTERS.

• PROTECTION AGAINST DANGEROUS MATTERS

At the end of its life, must be collected separately. It shouldn’t be thrown as urban waste and neither released in the environment.
It must be collected from the nearest special waste collection point or consigned to your dealer that provides the service. 
The incorrect waste disposal can damage the environment and the people for the presence of dangerous substances. 
Sanctions are provided for an unauthorized disposal.  ............................................................................................................................................................

• PROTECTION AGAINST FIRE

1) Maintain minimum distance of 0.1 meter from walls or any other type flammable surfaces.
2) Maintain minimum distance of 0,1 meter to lighted objects.
3) Replace fuses (if present) only with the specified type and rating.
4) Do not install the fixture close to heat sources. Do not lay the connection cable on the fixture when it is warm.
5) Fixture designed to be installed on normally flammable surfaces.   .....................................................................................................................................

• PROTECTION AGAINST ELECTRIC SHOCK

1) This equipment must be earthed.
2) Class I equipment. The power supply cord includes a protective earthing conductor as part of the cord.
3) Disconnect power before servicing (service personnel).   ..................................................................................................................................................

• PROTECTION AGAINST MECHANICAL HAZARDS

1) Use secondary safety chain when fixing this equipment.
2) Equipment surface may reach temperature up to 75°C. 
3) The protection screens and the lenses must be replaced with genuine parts only if they are visibly damaged and 
    their effectiveness has been reduced, for example, by cracks or deep scratches.   ..............................................................................................................

...................................................................................................................  ITA

INFORMAZIONI DI SICUREZZA (personale di servizio)

IMPORTANTE !

LEGGERE ATTENTAMENTE TUTTI GLI AVVERTIMENTI PRIMA DI COMPIERE QUALUNQUE OPERAZIONE SU QUESTO APPARECCHIO.  
ISTRUZIONI PER PREVENIRE LESIONI O DANNI DOVUTI AL FUOCO, ALLE SCOSSE ELETTRICHE, AI RISCHI MECCANICI ED A SOSTANZE PERICOLOSE.

•PROTEZIONE CONTRO SOSTANZE PERICOLOSE                                

A fine vita è oggetto di raccolta separata, non gettare nei comuni cassonetti di rifiuti urbani, né tantomeno nell’ambiente. 
Può essere consegnato presso i centri di raccolta delle amministrazioni comunali, oppure presso i rivenditori che forniscono questo servizio. 
Lo smaltimento errato può causare danni alle persone e all’ambiente per la possibile presenza di sostanze pericolose. 
Sono previste sanzioni in caso di smaltimento abusivo dei suddetti prodotti.  ..........................................................................................................................

•PROTEZIONE CONTRO IL FUOCO

1) Mantenere la distanza minima di 0.1 metri da pareti ed altre superfici infiammabili.
2) Mantenere la distanza minima di 0,1 metri dagli oggetti illuminati.
3) Sostituire i fusibili (se presenti) solo con altri dello stesso tipo e valore.
4) Non installare il faro vicino fonti di calore. Non appoggiare il cavo di connessione sul faro quando questo è caldo.
5) Questo apparecchio è adatto per il montaggio su superfici normalmente infiammabili.  .......................................................................................................

•PROTEZIONE CONTRO SCOSSE ELETTRICHE

1) Questo apparecchio necessita di messa a terra.
2) Apparecchio di Classe I. Il conduttore di protezione deve far parte del cavo di alimentazione.
3) Disconnettere l’alimentazione prima di aprire l’apparecchio (personale di servizio).  ............................................................................................................

•PROTEZIONE CONTRO RISCHI MECCANICI

1) Usare la catena di sicurezza supplementare quando installate l’apparecchio.
2) La temperatura dell’apparecchio può raggiungere 75°C.
3) Gli schermi di protezione e le lenti devono essere sostituiti sempre con ricambi originali se sono visibilmente danneggiati 
    e se la loro efficacia è stata ridotta, per esempio, da fessure o incisioni profonde. ...............................................................................................................

F

IP20

0,1 m

F

IP20

0,1 m

Содержание THEATRE MONOCHROMATIC 1860

Страница 1: ...User manual for art 1860 1861 1862 Manuale d uso per art art 1860 1861 1862 MONOCHROMATIC series Theatre...

Страница 2: ...rel 2_5 19 Studio Due 2...

Страница 3: ...Collegamento fonte di alimentazione Page 10 DMX connections Connessioni DMX page 11 DMX Channels Canali DMX page 11 Frost lter installation Installazione ltro frost Page 12 Example of connections DMX...

Страница 4: ...ONI DI SICUREZZA personale di servizio IMPORTANTE LEGGERE ATTENTAMENTE TUTTI GLI AVVERTIMENTI PRIMA DI COMPIERE QUALUNQUE OPERAZIONE SU QUESTO APPARECCHIO ISTRUZIONI PER PREVENIRE LESIONI O DANNI DOVU...

Страница 5: ...ser manual Studio Due warranty CE standards ITA INTRODUZIONE CONTROLLATE CHE L APPARECCHIO NON ABBIA SUBITO ALCUN DANNO DURANTE IL TRASPORTO SE AVESSE SUBITO DEI DANNI O SE NON DOVESSE FUNZIONARE RIVO...

Страница 6: ...tion Intelligent temperature control Flicker free function Smooth dimming function Halogen simulation RDM Control Con guration or individually by DRS remote control device DMX channels 3CH mode 1CH mo...

Страница 7: ...tion Smooth dimming function Halogen simulation RDM Control Con guration or individually by DRS remote control device DMX channels 3CH mode 1CH mode Strobe effect 0 5 25 Hz ITEM FIXTURE THEATRE 600 PL...

Страница 8: ...295Vac Frequency range 47 63Hz Power factor 0 90 Inrush current 13A Working temperature 30 45 Physical WxDxH 255x225x175 mm Weight 3 Kg Tested and work properly with the following dimmer units Zero 8...

Страница 9: ...one dell apparecchio in caso di sostituzione del cavo di alimentazione fare riferimento alla TABELLA SEZIONE CONDUTTORE ATTENTION HIGH VOLTAGE ALWAYS DISCONNECT THE MAINS SUPPLY BEFORE ACCESS TO THE C...

Страница 10: ...X 512 systems have the terminal resistor tted in the end of DMX line TERMINALE LINEA DMX L incorretto o il mancato collegamento del terminale di linea probabilmente la pi comune causa del difettoso fu...

Страница 11: ...NSTALLATION OF THE WIDE BEAM DIFFUSION FILTER INSTALLAZIONE DEL FILTRO DIFFUSORE 1 Slightly loosen the two pawls P and slide the panel P1 2 Insert the frost lter F into the slot with the rough side fa...

Страница 12: ...na sola linea di uscita DMX 512 lunga oltre 150 mt LINE 150 mt with microphonic or audio cable LINEA 150 mt con cavo microfonico o audio DMX Example 3 Esempio 3 SIGNAL AMPLIFIER AMPLIFICATORE DI SEGNA...

Страница 13: ...aster Slave function The device is powered through battery DRS il nuovo concetto dell illuminazione LED per uso professionale nelle installazioni esterne permanenti Gli apparecchi LED possono essere c...

Страница 14: ...Il pulsante ENTER permettere di entrare in un menu o di confermare una opzione in caso di lampeggio del parametro Il pulsante ESC annulla una operazione o torna al livello di menu inferiore ENG SETUP...

Страница 15: ...tore al quale stato associato Wireless bridge ULbr If wireless is ON enable the transmission of the received data by cable to the other xtures Se il wireless attivo consente la trasmissione dati agli...

Страница 16: ...rel 2_5 19 Studio Due 16 PHYSICAL DIMENSIONI...

Страница 17: ...irective ECM Directive 2014 30 EU EN 61000 3 2 2014 EN 61000 3 3 2013 EN 61547 2009 EN 55103 2 2009 EN 55015 2013 EN 55103 1 2009 A1 2012 Low Voltage Directive 2014 35 EU EN 60529 1991 A1 2000 A2 2013...

Страница 18: ...ballaggio Il costo di imballaggio del 2 sul prezzo netto per tutti gli articoli Detti prezzi possono essere soggetti a possibili variazioni per eventuali aumenti dei costi di produzione o imposte La m...

Страница 19: ...rel 2_5 19 Studio Due 19 this page is intentionally left blank questa pagina stata lasciata intenzionalmente bianca...

Страница 20: ...essere soggette a variazioni senza preavviso Head Of ce STUDIO DUE s r l I Str Poggino 100 01100 Viterbo Italy tel 39 0761 352520 fax 39 0761 352653 info studiodue com www studiodue com for technical...

Отзывы: