BEFORE USING
Read all cautions and warnings to page 1 prior to install this equipment. Particularly, read the follow:
1) Disconnect power before lamp’s replacement or servicing (service personnel)
2) Do not open the lamp cover for 300 seconds after switching off
3) Wear gloves and goggles to re-lamping or to work inside the unit (service personnel)
Before connecting the equipment to the power system: make sure that the mains voltage and frequency correspond to rated values.
• The CityColor can be equipped for a mains voltage 230VAC, 50 or 60Hz
on request: 208Vac, 60Hz; 200Vac, 50Hz
For a power supply of 100V-120V it is necessary to use one auto transformer with the following features:
• Output voltage 230V
• Output current 15A (for art. 0002 - art. 0005)
• Output current 20A (for art. 0003 - art. 0006)
The power supply cords construction is shown in pict.1. For connection to the mains supply proceed as pict.1.
The equipment must be connected to branch circuit having a circuit-breacker In=16A • Id=0.03A (230VAC) (art. 0002 - art. 0005) or
In=32A • Id=0.03A (230VAC) (art.0003 - art. 0006)
a) Do not install the spot close to the heat sources. Observe minimum distance between the spots of 1.5 meters. Do not lay the
connection cable on the spot when it is warm.
b) This unit must be positioned as to allow its ventilation. Be careful not to acclude the in-out ventilating grilles.
c) The unit must be positioned at least 50cm. from walls or other flammable surfaces.
d) Observe minimum distance to lighted objects of 5 meters.
External surface temperature Ta 35°C:
• After 5 minutes work; Tc=75°C.
• Once the thermic balance has been obtained; Tc=100°C.
4) The protection screens, the lenses, or the ultraviolet filters must be replaced if they are visibly damaged and their effectiveness
has been reduced, for example, by cracks or deep scratches.
5) The lamp must be replaced if it has been damaged or thermally deformed.
6) Clean regularly the in-out ventilating grilles.
7) Do not handle the spot by taking it by the head, but always by using the special handles.
WARNING
!
IP 67
pict.1
The equipment must be earthed.
IP 54 grade: the equipment must be installed on the horizontal
plane.
INPUT CONNECTOR
FOR 1800W
INPUT CONNECTOR
FOR 2500W HIGH POWER
IP 67
3 PIN CONNECTOR FOR POWER INPUT
L =1) NEUTRAL
N =2) LIVE
=3) EARTH
Содержание CityColor IP54
Страница 1: ...INTERNATIONAL PATENT WO99 40361 IP 54 User s and operator s manual for art 0002 0003 0004 0005...
Страница 14: ...12 APPENDIX A Here below you can find the complete list of DMX values ref page 8...
Страница 15: ...13 APPENDIX B Here below you can find the complete list of the available games ref page 11...
Страница 17: ...24 DATA LINK 512 DMX TOUBLESHOOTING DATA LINK 512 DMX TOUBLESHOOTING Appendix C Table A2 Appendix C Table A2...