The Transfer system is protected against overload with an automatic safety fuse on the AC Input 
side of the COMPACT. If the system has been overloaded the button/pin of the fuse will pop-out. 
To put the automatic safety system back in to operating you must push this pin back.  
Note: In the Inverter operation, The COMPACT generates a true sinusoidal and quartz stabilized 
output voltage. When, however the COMPACT is supplied from a grid or a generator and the 
transfer contact is active, then you have at the output AC OUT the same voltage as that at the 
input. This voltage can not be modified by the COMPACT! 

4.7.1  Set the transfer voltage threshold 
The voltage threshold of the transfer can by adjust between 150 to 230V with the turning knobs 
(23). From factory this value is 200V. Most of appliances can work on this voltage. When the Input 
voltages reach the settled value on turning knob, the inverter switch off and the AC INPUT go 
directly on the AC OUTPUT. When the voltage INPUT is less of 20V the value set, the transfer is 
stop and the OUTPUT switch back on the inverter.  
 
Don’t use the turning knobs “TRANSFERT” (23) to adjust the AC OUTPUT voltage! 
This is only it’s only a voltage threshold level to enable or disable the transfer. 

4.7.2  FAST (UPS)- MODE for the Transfer Switch 
The quick and break free Transfer mode is programmed with a slide switch „Transfer Delay“ OFF, 
which is on the front side (cable connections side). 
The aim of the COMPACT is to supply the consuming device with a break-free alternating voltage. 
When the incoming voltage AC IN no longer matches values which have been set with the Turning 
Knob 23, the Inverter switches on at once. The transfer is carried out in 0.02 seconds. This quick 
transfer ensures a break-free function for most consuming devices. If you have an alternating 
voltage back at the input AC IN, transfer system starts up again without any break, and the inverter 
is stopped.  

4.7.3  Delayed mode of the Transfer System 
The delayed mode of the transfer system „Transfer Delay ON“ is programmed with the slide switch 
on front with the cable connections. The COMPACT provides a break-free alternating voltage for 
the consuming device. A quick transfer switch is not always sensible nor is it always desired.  For 
example, when the consuming devices are operated by a small back-up generator. An overload of 
a short duration on such a generator, i.e. start of a vacuum cleaner etc., has the effect of 
decreasing the voltage for a short time. As in such cases the transfer to the Inverter is not 
desirable, the transfer system can be programmed with a delay. When the slide switch (Transfer 
delay) is in the „On“ position, the transfer to the inverter takes place with a delay of 5 seconds. If 
the voltage falls below 100Vac, the transfer takes place without delay! The transfer switching to the 
Inverter takes place without any break. 

4.8  The Solar charge controller (option) 

The COMPACT also has a Solar Charge Controller built in. For charging the batteries, Solar 
modules can be connected to the screw terminal SOLAR +/-. The in-built controller is a „Shunt 
controller“ for the maximum input current of 30A for C 1600-12 and C 2600-24 and 20A for C 4000-
48. The operating voltage of solar panels to be connected must match the actual operating voltage 
of the COMPACT and never exceeds the max. rated value. 
 
Under no circumstances should any other systems such as wind-generator be connected at the 
input of the Solar Charge Controller. 
The Solar Charge Controller works automatically and is always in operation. As soon as the energy 
is delivered from the Solar Charge Controller, LED 3 “SOLAR CHARGE” is lit and the batteries are 
being charged. The Solar Charge Controller works even when the Battery Charger is functioning. 
The way of working is the principally the same as that of the Battery Charger. The function is 
described in the section on Battery Charger. The programming and the adjustments are carried out 
in accordance with the same conditions. Check with your battery supplier which adjustments must 
be carried out for your battery.  

Содержание COMPACT C 1600-12

Страница 1: ...em COMPACT C 1600 12 COMPACT C 2600 24 COMPACT C 4000 48 Temperature sensor CT 35 Remote control RCC 01 Solar charge controller Cxxxx S Remote power sharing RPS 01 AC cable cover CFC 01 IP 23 top cover C IP23 STUDER INNOTEC TEL 41 0 27 205 60 80 Rue des Casernes 57 FAX 41 0 27 205 60 88 CH 1950 SION info studer innotec com ...

Страница 2: ... 9 3 4 CONNECTING PLAN FRONT SIDE 9 3 5 CABLING WIRING 10 3 5 1 PRE INSTALLATION SETTINGS 10 3 5 2 CONNECTION TO BATTERY 10 3 5 3 CONNECTION THE 230VAC CONSUMER DEVICE AC OUTPUT 10 3 5 4 CONNECTION THE 230VAC INPUT AC INPUT 11 3 5 5 CONNECT THE SOLARMODULES SOLAR ONLY FOR SOLAR OPTION 11 3 5 6 CONNECTION TO AUXILIARY CONTACT 11 3 5 7 CONNECTION TO REMOTE CONTROL 11 3 5 8 CONNECTION TO TEMPERATURE ...

Страница 3: ...XILIARY CONTACT 19 5 2 RESET VALUE 19 5 3 BATTERY VOLTAGES AND ABSORPTION TIME 19 5 3 1 TABLE OF VOLTAGE AND TIMING THRESHOLD 19 5 3 2 SET THE VOLTAGE AND TIMING THRESHOLD 20 5 4 PROGRAMMING THE AUXILIARY CONTACT 20 5 4 1 PRINCIPLE 20 5 4 2 THE PROGRAMMING OF THE AUXILIARY CONTACT IS CARRIED OUT IN THE FOLLOWING STEPS 20 5 4 3 EXAMPLES 21 5 4 4 MANUAL OPERATING OF AUXILIARY CONTACT 21 5 5 DISABLIN...

Страница 4: ... manual The warranty period for the COMPACT is 2 Years 1 3 Warranty Disclaimer We do not accept any responsibility for any damages occurring through use manipulation working situation and handling which are not explicitly mentioned in these operating instructions Following cases are not covered by the warranty High voltage at INPUT i e 48V at the Battery INPUT of COMPACT 1600 12 Reverse polarity o...

Страница 5: ...conditions The COMPACT may only be connected to lead acid or lead gel batteries Caution In normal use lead acid and lead gel batteries give out explosive gases Never smoke or allow a spark or flame in the vicinity of batteries The batteries must always be stored or placed in a well ventilated area they should be placed in such a way that there is no danger of short circuiting through carelessness ...

Страница 6: ...mergency generator or the AC network With the transfer system on one side you have an alternating voltage at the output for use by the connected consumer devices On the other side the batteries are charged The distribution of energy between the consumer devices and battery charger is automatic 2 2 3 The Battery charger The built in battery charger is so arranged that it can charge the batteries qu...

Страница 7: ...perating elements and displays with the exception of the level adjustment are available on the remote control The remote control is furnished with a 20m long cable This cable can go to 40m long On the remote control output power and charging current are also shown 2 3 Battery connections Lead acid batteries are normally available in blocks of 2V 6V or 12V In most cases to generate the necessary op...

Страница 8: ...of the COMPACT For that s release a little the too screws down and more the tow up Then it s possible to pass the IP 23 cover between the COMPACT and the wall The cover must touch the screws Lock on the four screws it s ready 3 3 Connection 3 3 1 General instructions on connecting The cable connection on the terminals AC INPUT AC OUTPUT 15A 230VAC are carried out with a screwdriver Nr 1 and the co...

Страница 9: ...nnecting terminal for Remote Control RCC 01 D Equalize Slide switch for equalization of the Battery E Transfer delay Slide switch for Transfer Delay F Temp Connecting terminal for Temperature sensor CT 35 Caution Check battery polarity before connecting A wrong connection could damage the system 16A 250Vac BATTERY SOLAR Remote control Temp Don t open before disconnect line and battery N AC Input A...

Страница 10: ...nnection Matching battery terminals matching fuse on a clamp Prepare battery cables if necessary press on cable tabs shoes Connect red cable on Plus Pole and the black cable on the Minus Pole On connecting the second cable to the battery pole a spark is produced because for a short time high current flows in the COMPACT to charge the capacitors For this reason follow strictly the safety measures d...

Страница 11: ... and voltage for this is 16A 250Vac The DEL 5 Contact active show the position of them alight mind active and off mind non active The schematic view of the connections on the front show the relay in the non active mode 3 5 7 Connection to Remote control The Remote Control RCC 01 is connected in the terminal marked Remote control with a RJ11 8 connector The Remote Control can be plugged IN or plugg...

Страница 12: ...tive Program STANDBY CHARGER Charger Invert er Program Change status Lock select CHARGER INVERTER RESET ALARM TRANSFER EQUALIZE 230V 25 1 3 4 5 21 6 2 14 23 22 24 7 8 20 10 11 12 13 19 15 16 17 18 9 Inverter output power 5 10 20 40 60 80 100 130 160 200 10 20 30 40 50 60 70 Charge current POWER MONITOR A 16A 0 INPUT LIMIT 26 4 Operating 4 1 Display and operating control elements ...

Страница 13: ...ort circuit 12 Batt Low High Battery voltage is too low Battery voltage is too high 13 OFF COMPACT is turned off Turning it back on is only possible manually COMPACT is for the time being turned off Turning it back on will follow automatically 14 Battery Charger and or Solar Charge Controller are doing an equalization cycle 15 18 Charge condition of Battery LED 15 Absorption time is running 25 CUR...

Страница 14: ... one after the other in a short time then it no longer switches on automatically The LED 13 remains lit Press the push button 19 ON OFF in order to switch on the Inverter 4 5 3 Overheating Over Temp If the Inverter has been overloaded for a long time or it has been working at too high surrounding temperatures it will switch off The LED 10 Over Temp is lit and the LED 13 OFF blinks After cooling do...

Страница 15: ... you must confirm with your supplier that the batteries are suitable for this process Equalization is recommended for the lead acid batteries in order to mix well the electrolyte fluid and to clean the lead plates Equalization mode should never be used when using Gel Batteries If the COMPACT is operating with a lead acid battery which is suitable for equalization the slide switch Equalize which is...

Страница 16: ...RRENT MONITOR 25 of the front panel or on the Remote Control 4 6 5 Battery Condition Built in microprocessor with a specially developed algorithm calculates the actual state of charge of the battery and displays it on LED 15 18 The LED 14 is lit when the system is carrying out a charge cycle with equalization For safety reasons you must get the recommended charge voltage and charge currents from y...

Страница 17: ...rter is stopped 4 7 3 Delayed mode of the Transfer System The delayed mode of the transfer system Transfer Delay ON is programmed with the slide switch on front with the cable connections The COMPACT provides a break free alternating voltage for the consuming device A quick transfer switch is not always sensible nor is it always desired For example when the consuming devices are operated by a smal...

Страница 18: ...e connected to the COMPACT All operating controls and displays except from level adjustment are available on the Remote Control The Remote Control is supplied with a 20m long cable It can be lengthened to 40m The Remote Control is suitable for surface mounting on the wall or on to a switch board It is fixed with 4 screws The COMPACT can also be programmed with the Remote Control The Programming is...

Страница 19: ... value When the COMPACT is to be connected to a battery or after an interruption RESET it is always programmed with these standard settings In order to get to these settings during operation you must press the three Push Buttons 19 20 21 simultaneously for a minimum of 2 seconds 5 3 Battery voltages and absorption time The voltage levels low voltage float charge end of charge and equalization and ...

Страница 20: ...upplier 5 4 Programming the auxiliary contact 5 4 1 Principle The Auxiliary Contact can be basically programmed for any operating situation of the COMPACT which is indicated with a LED The programming is possible for one or more operating situations If the contact is programmed for many situations it is activated as soon as the COMPACT finds itself in any one of the programmed situations That mean...

Страница 21: ... can also be used as a twilight switch i e to operate automatically the exterior lighting With it the connected solar modules measure the light intensity If the COMPACT is operating without solar modules and a twilight switching function is desired you can connect small solar cells with the nominal voltage of the COMPACT on to the SOLAR terminals for the purpose of measuring the light intensity To...

Страница 22: ... continuously even if there is a correct AC voltage at the input CHARGER INVERTER AC OUT AC IN 1 2 7 8 9 Inverter and charger are both disabled Only the transfer switch function is enabled in input voltage and frequency is OK 6 Maintenance Apart from the periodic controls mentioned for the connections the COMPACT does not need any maintenance Keep the appliance clean and from time to time wipe it ...

Страница 23: ... 61000 3 2 Optional solar charger 4 stages I U Uo Equalize every 25 cycles Maximum PV open circuit voltage V 25V 45V 90V Maximum charge current A 30A 30A 20A Working principle I U Uo Equalize every 25 cycles Shunt Battery control thresholds and times adjustable by the user Absorption time 0 4 h End charge cycle voltage 14 4V 28 8V 57 6V Floating voltage 13 6V 27 2V 54 4V Equalization voltage 15 6V...

Отзывы: