7. Setting of the parameters
A full list of accessible parameters can be found in Chapter 8 (p. 23).
7.1. Generalities
The configuration is carried out on the remote control RCC -02/-03 by means of the BSP parameters menu.
Generally the settings described in Chapter 5: “Quick Start guide” (p. 16) are enough for a good operation of
the BSP. It is however possible to modify many other parameters described in this chapter.
7.2. Levels of use and of accessibility
The functions described below correspond to the level EXPERT. As per the user level selected, the access
to all these functions might not be possible. Do refer to the chapter user level setting in the remote control
RCC -02/-03 manual for more information about this matter.
7.3. Basic settings {6000}
The parameters for a basic configuration of the BSP are in this menu.
7.3.1. Nominal capacity {6001}
Nominal battery capacity. It is indicated for the nominal discharge time defined by the parameter {6002}.For
instance 203Ah.
7.3.2. Nominal discharge time (C-rating) {6002}
Discharge time needed to give the battery nominal capacity of the parameter {6001}. For instance C5/C10/
C20/C100.
7.3.3. Nominal shunt current {6017}
This parameter enables to adjust the BSP measurement to the shunt. It must be set according to the nominal
voltage of the shunt (parameter {6018}). For instance for the shunt 1200 A supplied with the BSP-1200, the
setting will be 1200A and 50mV.
7.3.4. Nominal shunt voltage {6018}
See parameter {6017}.
7.3.5. Reset of battery history {6003}
This parameter enables to reset to zero all counters of the Section 6.2 and the algorithm during installation
on a new battery.
This parameter should normally not be used if the battery has not been changed,
because then the history (total current, estimated capacity) is lost.
7.3.6. Restore default settings {6004}
Use this parameter to restore the initial settings of the BSP.
If your installer has made some settings at "installer" level while commissioning your
installation, this function restores his settings and not the factory ones.
7.3.7. Restore factory settings {6005}
Содержание BSP 1200
Страница 1: ...Battery Status Processor BSP User Manual Copyright 2011 Studer Innotec SA V1 0 3 ...
Страница 2: ......
Страница 4: ......
Страница 13: ...Studer Innotec SA BSP User Manual V1 0 3 13 3 2 Exploded view Figure 3 2 Exploded view ...
Страница 22: ...Studer Innotec SA BSP 22 V1 0 3 User Manual See explanation at parameter 6042 ...
Страница 26: ......
Страница 27: ......