![Stubbe CFP Series Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/stubbe/cfp-series/cfp-series_original-operating-manual_1386392008.webp)
Appendix
9
Appendix
9.1
Technical data, operating limits,
dimensions and weights
The particulars are described on the data sheet (→ Data
sheet).
9.2
Connection diagrams
9.2.1
Description of the contact points
2-rod probe
2 1
Fig. 3
Contact points for 2-rod probe (example)
1
Reference (black probe)
2
Minimum/maximum (relay 4 / blue probe)
3-rod probe
2
1
3
Fig. 4
Contact points for 3-rod probe (example)
1
Reference (black probe)
2
Maximum (relay 4 / blue probe)
3
Minimum (relay 3 / red probe)
9.2.2
Connection diagrams
Filling level indicator
Fig. 5
Connection diagram, filling level indicator
Terminal
Connection
+
Voltage supply (18...30 V DC)
-
Voltage supply (0 V)
X
Potentiometer for adjusting the sensitivity
1
–
2
–
3
Relay 3 (NO)
4
Relay 4 (NO)
Com
Relay 1...4 (COM)
Tab. 5
Connection diagram, filling level indicator
8
CFP
BA-2022.08.31 EN
302 483