background image

Technical data, operating limits, dimensions and weights

8

Troubleshooting

WARNING

Risk of injury and poisoning due to hazardous or hot
media!

Use personal protective equipment when carrying out any
work on the fitting.
Safely collect the media and dispose of it in accordance
with environmental regulations.

Consult with the manufacturer regarding faults which are not
identified in the following table, or which cannot be traced to
the indicated causes.

Error

Possible cause

Corrective action

Fitting installed the wrong way round.

Check the direction of flow in the fitting

(→ 3.4 Direction of flow, Page 6).

if

necessary install the fitting correctly

(→ 5.3 Installing fitting in pipe, Page 7).

Fitting is not sealing.

Ball/float or the associated O-rings
dirty or worn.

Clean and if necessary replace the ball/float
and associated O-rings

(→ 7.2.2 Cleaning/

replacing the ball/float and O-rings, Page 8).

Medium is leaking from the
housing.

O-ring on the housing worn.

Replace the O-ring on the housing

(→ 7.2.2 Cleaning/replacing the ball/float
and O-rings, Page 8).

Fitting installed the wrong way round.

Check the direction of flow in the fitting

(→ 3.4 Direction of flow, Page 6).

if

necessary install the fitting correctly

(→ 5.3 Installing fitting in pipe, Page 7).

Vessel is not being aerated
(B895).

The ball/float is stuck in position by
the seal.

Clean and if necessary replace the ball/float
and associated O-rings

(→ 7.2.2 Cleaning/

replacing the ball/float and O-rings, Page 8).

Ensure that the fitting is suitable for the medium in
question (→ resistance list).

The fitting is stuck in the
„Closed“ position: The vessel is
pressurized.

Drain the medium out of the vessel until the ball/float
is released from the valve seat and the air can
escape.

Vessel is not being vented
(BE891).

The fitting is stuck in the
„Closed“ position: The vessel is
depressurized.

Clean and if necessary replace the ball/float,
valve seat and O-rings

(→ 7.2.2 Cleaning/

replacing the ball/float and O-rings, Page 8).

Ensure that the fitting is suitable for the medium in
question (→ resistance list).

Tab. 3

Troubleshooting

9

Technical data, operating
limits, dimensions and weights

The particulars are described on the data sheet (→ Data
sheet).

302 464

BA-2022.08.25 EN

B895, BE891

9

Содержание B895

Страница 1: ...2 08 25 EN Print No 302 464 TR MA DE Rev001 ST BBE GmbH Co KG Hollwieser Stra e 5 32602 Vlotho Germany Phone 49 0 5733 799 0 Fax 49 0 5733 799 5000 E mail contact stuebbe com Internet www stuebbe com...

Страница 2: ...1 Preparations for installation 6 5 2 Planning pipelines 6 5 3 Installing fitting in pipe 7 5 3 1 Connection with solvent welding butt weld spigot ends 7 5 3 2 Connection with union nut and insert 7 5...

Страница 3: ...fied employees with additional training for fitting the respective pipework Electrical qualification Qualified electrician Responsibility Read observe and follow this manual and the other applicable d...

Страница 4: ...llowing safety aspects are observed and monitored Intended use Statutory or other safety and accident prevention reg ulations Safety regulations governing the handling of haz ardous substances Applica...

Страница 5: ...ed by the system operating company Type BE891 for aerating and venting Valve Open at depressurization venting and during filling due to the weight of the closure element valve Closed due to flotation...

Страница 6: ...al protective equipment when carrying out any work on the fitting Before disposing of the fitting Collect escaping medium and dispose separately according to local regulations Neutralize residues of m...

Страница 7: ...and tighten the union nut 5 4 Performing the hydrostatic test Pressure test using neutral medium e g water 1 Pressurize the fitting ensuring Test pressure permissible system pressure Test pressure 1 5...

Страница 8: ...5 on the cleaned float 9 Assemble the parts BE891 size DN10 50 Fitting disassembled 1 Unscrew the screw in part 3 2 Replace the O rings 4 5 3 Clean the ball 6 or if damaged replace it 4 Assemble the...

Страница 9: ...replacing the ball float and O rings Page 8 Fitting installed the wrong way round Check the direction of flow in the fitting 3 4 Direction of flow Page 6 if necessary install the fitting correctly 5 3...

Отзывы: