Stuart Turner Mainsboost Charger MBC 12 Скачать руководство пользователя страница 12

- 12 -

6 ELECTRICAL

6.11

 Regulations:

 The electrical installation must be carried out in 

  

 

accordance with the current local regulations by a qualified person.

6.12

 Safety:

 In the interests of electrical safety a 30 mA residual current 

  

 

device (

R.C.D. not supplied

) should be installed in the supply 

  

 

circuit.  This may be part of a consumer unit or a separate unit.

6.13  Before starting work on the electrical supply ensure power supply 

  

 

is isolated.

6.14

  DO NOT

 allow the supply cord to contact hot surfaces, including 

  

 

the motor shell, pump body or pipework.  The cord should be 

  

 

safely routed and secured by cable clips.

6.15

 Earthing:

 This appliance must be earthed via the supply cord, which must be   

 

correctly connected to the earth point located in the terminal box.

6.16

 Connections:

 The pump must be permanently connected to the fixed wiring   

 

of the mains supply using the factory fitted supply cord, via a dedicated  

 

 

double pole switched fused spur off the ring main.

6.17 

Wiring of connection unit:

WARNING: This appliance must be earthed.

 

The wires in the mains lead (supply cord) are coloured in accordance with the  

 

following code:  

 

 

Green and Yellow:  Earth

 

 

Blue:  Neutral

 

 

Brown:  Live

 

As the colours of the wires in the mains lead of this appliance may not  

 

 

correspond with the coloured markings identifying the terminals in your  

 

 

connection unit proceed as follows:

 

z

The wire which is coloured green and yellow must be connected to the    

  terminal in the connection unit which is marked with the letter E or by the  
  earth symbol: 

 or coloured green or green and yellow.

 

z

The wire which is coloured blue must be connected to the terminal which  

  is marked with the letter N or coloured black.

 

z

The wire which is coloured brown must be connected to the terminal  

 

  which is marked with the letter L or coloured red.

Содержание Mainsboost Charger MBC 12

Страница 1: ...t Charger units Mainsboost Charger Pump MBC 12 Bypass Kit Wall Mounted Mainsboost Charger Installation Operation Maintenance Instructions Please leave this instruction booklet with the home owner as i...

Страница 2: ...tent and reliable water services Installation parameters must not exceed the values given in the technical specifications STORAGE If this product is not to be installed immediately on receipt ensure t...

Страница 3: ...ren without supervision z Maximum head closed valve 43 metres z The motor casing can become very hot under normal operating conditions Care must be taken to ensure it cannot be touched during operatio...

Страница 4: ...g and securing details are carefully noted to ensure re assembly to the same factory pattern is always maintained z If the supply cord is to be changed or is damaged it must be replaced with a special...

Страница 5: ...ackage 2 1 Ball valve 1 2 Single check valve 1 Your product may vary slightly from the picture above IMPORTANT Your Mainsboost Charger MBC 12 system will be delivered in two boxes Please check the con...

Страница 6: ...he mains is supplemented by the water from the Mainsboost unit to provide a balanced supply at consistent pressure to downstream services On occasions where the static pressure is less than 2 bar a ch...

Страница 7: ...re pipework Ensure pipework to and from the Mainsboost Charger MBC 12 is independently supported clipped to prevent forces being transferred to inlet and outlet branches of pump Flexible hoses supplie...

Страница 8: ...pump in a location where in the unlikely event of a water leak any spillage is contained or routed to avoid electrics or areas sensitive to water damage 3 16 Static inlet pressure Ensure the static i...

Страница 9: ...and the Mainsboost vessel 4 12 System Designation It is important to understand what upstream and downstream refers to before starting the installation Upstream The term Upstream refers to the system...

Страница 10: ...unit Fig 4 1 Fit mounting plate onto wall ensuring level Fig 5 2 Hook pump assembly onto mounting plate and secure in place using M6 set screw Fig 5 Fig 5 Fig 4 Mounting plate Pump assembly M6 set scr...

Страница 11: ...he most convenient way select the best route 5 Care should be taken not to kink the hoses or bend them through an angle greater than 30 degrees 6 Route 15 mm feed and return from the tees inserted in...

Страница 12: ...anently connected to the fixed wiring of the mains supply using the factory fitted supply cord via a dedicated double pole switched fused spur off the ring main 6 17 Wiring of connection unit WARNING...

Страница 13: ...to the same factory pattern is always maintained 6 21 If the supply cord is to be changed or damaged it must be replaced by a special cord available from Stuart Turner or one of its approved repairers...

Страница 14: ...d leave outlet taps open 7 13 Check the chart below for the correct pump pressure setting against the static mains pressure recorded Warning NOTE PRV setting must not exceed 5 0 bar Refer to the Mains...

Страница 15: ...the up down arrows to change the selected parameter s to the desired value z After changing the required parameter s press the set button twice in quick succession to lock the new value into the contr...

Страница 16: ...ist filling of the system z Close Mainsboost vessel isolation valve z Allow the pump to continue running until air has been completely purged from the system all outlets will have to be opened and clo...

Страница 17: ...xible hoses Connections 15 mm push in x G female x 235 mm long 15 mm push in x G female x 200 mm long Motor Type Induction thermal trip auto reset Duty rating Continuous S1 Electrical Power supply Vac...

Страница 18: ...9 12 Alarm fault codes All alarms automatically reset except Prt and PF1 Displayed message Fault description Action A Hnt high temp cut out Pump head overheating head temperature has exceeded the set...

Страница 19: ...overed by this warranty Damage arising from incorrect installation improper use unauthorised repair normal wear and tear and defects which have a negligible effect on the value or operation of the uni...

Страница 20: ...0 3 3 BS EN 61000 4 2 BS EN 61000 4 3 BS EN 61000 4 4 BS EN 61000 4 5 BS EN 61000 4 6 BS EN 61000 4 11 EMF Directive 1999 519 EC BS EN 62233 RoHs Directive 2011 65 EU WEEE Directive 2012 19 EU IT IS H...

Отзывы: