- 7 -
Cont ...
3.19
Fuse:
All models should use 13 Amp fuse.
3.20
Supply cord replacement:
The internal wiring within the terminal box is routed and
secured to ensure compliance with the electrical standard
EN 60335-1. It is essential that prior to any disturbance of
this internal wiring, all cable routing and securing details are
carefully noted to ensure re-assembly to the same factory
pattern is always maintained.
3.21 If the supply cord is to be changed or damaged, it must be replaced by a special
cord available from Stuart Turner or one of its approved repairers.
3.22
Cable Gland Fitting Instructions:
To enable correct assembly of the cable gland the
‘O’-ring (Fig. 5 item 1) must be placed over the cable
before the clamping insert (Fig. 5 item 2) can be
tightened.
Note: Cable diameter range:- 9.2 mm to 11.9 mm.
3.23
Supply Cord Extension:
The pumps are fitted with a supply cord to the
following specification:-
All models . . . . . . . . . . . . . . HO7RN-F3 G 1.5 mm² - 10 Amp rated cable.
If the supply cord is to be extended, a cord of the same specification should be
used. Any connections or junction boxes used should be specifically suited for
the application and installed in accordance with the manufacturers instructions.