User Instructions for DD11-N95-5 particulate respirator
October 2021
IIMP790000 US01
Carefully read the instructions before use to understand thoroughly the contents and to use the respirator correctly.
Keep the instructions at hand for future reference. If you lose the instructions, contact the distributor for another copy.
■
Definition of Warning Label
DANGER, WARNING and CAUTION described in the Instructions indicate im-
portant matters you should understand to avoid possible accidents due to mis-
use of the product. The respective symbols have the following meanings:
DANGER
Misuse would likely result in death or serious health
hazards to the wearer.
WARNING
Misuse could cause death or serious health hazards
to the wearer.
CAUTION
Misuse could cause health risks or property damage
to the wearer.
■
Precautions for Use
Before occupational use of this respirator, a written respiratory protection pro-
gram must be implemented meeting all the local government requirements. In
the United States, employers must comply with OSHA 29 CFR 1910.134 which
includes medical evaluation, training, and fit testing.
Please observe the following precautions for safe use of the respirator.
Misuse may jeopardize the life of the wearer.
DANGER
1.
Never use the respirator under the following conditions which may
result in death or serious health hazards.
• In an environment where the oxygen concentration is less than 19.5 %.
• In an environment where contamination materials are unknown.
• In an environment where there is toxic gas, vapor, or oil mist.
• In an environment where contamination materials pose immediate
danger to life or health.
2.
Never use the respirator except for the specified application
within the specified use range.
WARNING
1.
Do not disassemble or modify the respirator.
2.
Do not wear the respirator if you are characterized by any of
the following cases.
• If you have beards, whiskers, etc., do not use with beards that pre-
vent direct contact between the face and the respirator.
• If you have a respiratory or circulatory system disease.
• If you are out of shape
3. Be sure to conduct the prior-to-use check.
4.
Do not put anything between your face and the respirator.
5.
Remove the respirator in a safe place if any of the following occurs.
• If the inhalation resistance increases.
• If any part is broken.
• If you feel your health condition is not good.
6. Be sure to replace the respirator with a new one when it is con-
taminated, damaged or deformed substantially.
7.
Do not wash the respirator, otherwise the filter efficiency may
decrease.
8.
Do not blow off the dust adhered to the respirator induced by
compressed air because it may cause a decrease of filter ef
-
ficiency.
9.
This respirator is sensitive to shock. Do not bang or slam down
the respirator because it may cause a decrease of filter efficiency.
10.
The storage period of the respirator is two (2) years from the date of
manufacture in a sealed condition. Do not use the respirator after
the storage period has expired.
11. Dispose of the respirator after each use. Never reuse the respirator.
CAUTION
1.
This respirator may cause a rash, red flare, itch, or some other
symptom due to an allergic reaction, hazardous substances in
the environment, or sweat. In that case, stop wearing the respira
-
tor and consult with a dermatologist, etc. (Continued use may
worsen the symptom.) Especially if you are allergic, stop wearing
the respirator immediately when a rash, red flare, itch, or some
other symptom appears.
■
Applications and Scope of Use
The respirator is designed to protect humans from hazardous particulates in
environment. The respirator is approved by US NIOSH as Class N95. It also
conforms to the “Guidelines for prevention of tuberculosis infection in medical
facilities” set by the CDC (Centers for Disease Control and Prevention).
The respirator shall not be used in the following conditions:
1. In an environment where the oxygen concentration is less than 19.5 %.
2. In an environment where there is toxic gas, vapor, or oil mist.
CAUTION
The respirator has not obtained the national certifica
-
tion of Japan. Please do not use it for industrial hy-
giene measures in Japan.
■
Features
1.
The respirator is made of electret filter media and is easy to use.
2. Polyester jersey of the face seal cloth has improved wearing comfort.
3.
The length of the straps is adjustable so that it can be fit to any wearer.
4. The respirator has no metallic part. Therefore, it does not require separation for dis-
posal.
■
Performance
Item
NIOSH standard (N95)
Filter efficiency (
NaCl
)
[%]
95 or more
Inhalation resistance at 85
flow
[Pa]
105 or less
Exhalation resistance at 85
flow
[Pa]
105 or less
■
Structure and Name of Each Part
Upper strap
Buckle
Exterior View
Filter media
Interior View
Side View
Inner frame
Face seal cloth
Approval label
Lower strap
■
Check before donning
Wearer must check the following items before use.
If you find any failure or defect, please replace the respirator with a new one.
1.
Check that the respirator is free from fissures or holes.
2. Check that the respirator is not dirty.
3.
Check that the straps have a sufficient elasticity.
■
How to wear and remove the respirator
<Wearing the respirator>
Lower
strap
Buckle
Approval
label
1. Correctly position the respirator’s top and bottom so as to set the approval lavel
downward. Then stretch out the lower strap with both hands and place it around the
back of your neck.
2. Holding the respirator with one hand at the nose and mouth, place the upper strap
around your head using the other hand.
3.
If the fitness of the face and the mask is loose, adjust the strap length by pulling on
the ends of the strap.
N95