TECHNICAL PASSPORT,
INSTALLATION AND MAINTENANCE
MANUAL
Страница 1: ...TECHNICAL PASSPORT INSTALLATION AND MAINTENANCE MANUAL ...
Страница 2: ...General information 5 2 2 Pellet boiler 5 2 3 Fuel 6 3 TECHNICAL SPECIFICATIONS 7 4 CHIMNEY 8 5 CONNECTION TO THE HYDRAULIC SYSTEM 8 5 1 Installation in a closed system 8 6 ELECTRICAL INSTALLATION 9 7 BOILER OPERATION 9 7 1 General information 9 7 2 Accidental ignition of soot in a chimney 9 7 3 Cleaning and technical maintenance 9 8 ENVIRONEMNTAL PROTECTION 10 8 1 Packaging disposal 10 8 2 Boiler...
Страница 3: ...er should be done according to country s regulations and indications of this manual Otherwise the manufacturer does not accept responsibility for possible defects and is forced to terminate the product warranty 1 3 Installer advice When installing the boiler regulations and standards of a country in which the device will be operated in must be adhered to Country s construction standards which prov...
Страница 4: ...wing indications It can be learnt by asking your local installer or chimney sweep Minimum distance from boiler wall and chimney to material of average or high flammability must be at least 400 mm Minimum distance from flammable materials must be at least 600 mm If flammability is unknown 600 mm distance must be preserved Flammability of materials A non flammable Asbestos rocks bricks ceramic tiles...
Страница 5: ...e boiler installation must be confirmed by the installer by issuing a certificate of installation works 2 2 Pellet boiler The boiler is used to heat the water of the heating system The maximum outgoing water temperature is 85 C allowed operating pressure at the lowest point of the heating system 1 5 bar Technical data is presented in the annex table Pellet boiler composition 1 Boiler 2 Pellet hopp...
Страница 6: ...ent 0 5 1 7 1 50 Humidity 10 12 Humidity upon delivery Not specified Not specified Calorific value MJ kg 18 1 17 5 19 5 2 Sulphur 0 04 1 0 08 Nitrogen 0 3 1 0 3 Chlorine 0 02 1 0 03 Dust collected 2 3 Compression facilitators 2 8 4 Ash melting point Not specified Not specified Arsenic mg kg 0 08 0 08 Lead mg kg 10 10 Cadmium mg kg 0 5 0 5 Chromium mg kg 8 8 Copper mg kg 5 5 Quicksilver mg kg 0 05 ...
Страница 7: ...oiler hydraulic resistance Δt 10 C mbar Δt 20 C mbar 10 2 2 9 10 2 2 9 10 2 2 9 Chimney connection mm Ø 180 Ø 200 Ø 200 Chimney height from the floor mm 1550 1285 1549 Fuel consumption at nominal power kg h 4 5 5 5 6 0 Required chimney draft mbar 0 12 0 12 0 12 Boiler diameter mm 560 670 670 Boiler height mm 2100 1700 2100 Boiler weight kg 188 258 318 Door opening dimensions mm 245 x 215 245 x 215...
Страница 8: ... in the country of operation of the boiler The boiler flue must be connected to the steel part of the chimney of the correct size and shape The connection must be airtight It is recommended to install sealed measuring points in the chimney during installation We also recommend that you call a competent person to inspect and clean the chimney at least twice a year before and after the heating seaso...
Страница 9: ...cessary adjust the boiler combustion We recommend that you do not operate the boiler in the event of a malfunction and contact the service department of JSC Stropuva ir ko immediately Note After connecting and starting up the boiler the customer must be instructed by a competent person on the use and maintenance of the boiler For more information on starting and operating the boiler see the burner...
Страница 10: ...gulation of boiler combustion parameters maintenance cleaning replacement of parts of the set service life fuses electric heaters sealing gaskets are not included in the scope of warranty work and the responsibility for them lies with the user 4 The distributor is only liable under the terms of the warranty if the defect is due to the causes of the product sold or if a defect occurred in a physica...
Страница 11: ...er 8 JSC STROPUVA IR KO assumes no responsibility for indirect loss or damage resulting from additional inconvenience due to the inability to use the equipment or its components that are covered by the warranty Customer complaints about other defects that occur after delivery of the goods due to physical defects other than equipment defects are not accepted 9 All disputes indirectly or directly re...
Страница 12: ... I believe that shortcoming listed in the complaint were caused by defects of your product I ask you to send your representatives to inspect the connected device to determine and remove the defects If it will be found that mentioned defects were caused by inappropriate installation or use of device or if there are no warranty covered faults I commit to refund the expanses of transportation 0 25 Eu...
Страница 13: ...ranty is void In the event of a device failure a copy of this passport is to be sent to the respective seller or distributor The original passport is to be presented to the authorized repairer Model Serial No Nominal power Date of purchase Seller s stamp and signature Installer s stamp and signature Date of installation Date of first use Technical maintenance works ...
Страница 14: ...NICAL PASSPORT INSTALLATION AND MAINTENANCE MANUAL JSC Stropuva ir ko company code 300149972 Kęstučio g 1A Lentvaris Trakai dist LT 25144 Tel 370 5 255 17 63 mob 370 656 08961 www stropuva lt info stropuva lt ...