3
!
SETUP
!
INSPECTION
The hydraulic hose is shipped attached to the pump, with a threaded male connector at the
opposite end to the pump. Attach the male connector to the female connector on the ram and
screw the threaded collar all the way onto the male threads and hand tighten. Ensure ram is fully
retracted before detaching hose from ram.
AIR PURGE
From time to time, air may enter the hydraulic system and will need to be purged. Evidence of air
in the system is a “spongy” feel when pumping or an incomplete stroke on the pump.
Turn the release valve counterclockwise by 1-1/2 turns. With ram fully retracted and release valve
open, pump the handle 10-20 times
It is recommended to use a pressure gauge to monitor the pressure when using components that
reduce the capacity of the unit.
Visual inspection shall be made before each use of this equipment, checking for abnormal conditions,
such as cracked welds, leaks, damaged, loose or missing parts. This equipment shall be removed
immediately from service if it is believed to have been subjected to an abnormal or shock load, the
equipment shall be inspected by a qualified repair facility. Owners and / or operators should be aware
that repair of this equipment may require specialized knowledge and facilities. It is recommended
that this equipment be inspected annually by a qualified repair facility. Defective parts, decals, safety
labels or signs should be replaced with Strongarm specified parts.
Pressure Gauge
030285 – Pressure Gauge c/w adapter Block
NOTE: When adding threaded components to
this hydraulic system be sure to use a good
quality hydraulic thread sealant.
The Capacity chart on the left indicates
reduction in overall capacity based on various
extension and adapter configurations.