Display flashes “hot” (OVERHEAT)

• This indicates that the heater body is over 112ºF. The system should be shut down 

in this state and will re-start automatically when the water cools below 112ºF.

Display flashes “HL” (HIGH LIMIT)

• This indicates that either the heater or the spa has reached 118ºF or higher. The system will not re-start

automatically. To re-start the system, the water temperature must be below 112ºF and the heater key at
the topside control must be pressed.

Display flashes “FLO” (FLOW)

• This indicates that there is a water flow problem or defective pressure switch.
• make sure filters are clean
• check that service valves are open
• check for obstruction of flow
• adjust pressure switch (see pressure switch detail under description and use of controls)

Display flashes “FLC”*

• This indicates that the pressure switch is stuck in the closed position and should be replaced.

Erratic operation at topside panel* 

•Check for proper connection at J8
• Shut off system and restart
• Check for debris inside topside panel control housing
• Check cable connection at the topside  control remove, clean reconnect.
• Try new topside control 
• Replace main board

Pump(s), blower or light does not shut off*

• Try new topside control
• Replace main board

Circulation pump does not work*

• Check the fuse and power connections.

Light does not work

• Press Light to turn the light on/off. The Antigua Spa is equipped with an LED Multi-Color Light. The colors

will cycle as you press the light button on and off.

Freeze Protect Over-ride  FPO

This function is intended to be used on start-up after a fresh fill if water temp is below 52ºF.  The 6 hour dura-
tion of the FPO cycle is counted from the time the unit is powered-up and not from the time of its activation.

By pressing the Jets 1 and Light key simultaneously for 10 seconds, the freeze protect feature will be suspend-
ed for 6 hours. ( the FPO will be activated) This is to allow the installer of the spa to check for normal operation
if the spa is filled with water that is less than the set freeze protect level 52ºF. FPO will appear every 10 sec-
onds at the topside control. To manually go back to freeze protect mode, power down the system and re-boot.
It is recommended that the system be left on low speed and heating in FPO mode.

Troubleshooting

*indicates qualified service technician recommended

Содержание The Cyprus

Страница 1: ...108 Northumberland PA 17857 1 800 STRONG 9 1 800 787 6649 OWNER S MANUAL 2 15 06 CAUTION More than one GFCI used on the electrical circuit will render this spa inoperable This spa must be on a dedicated circuit ...

Страница 2: ...0 days of purchase voids all warranties provided by Strong Pools and Spas Table of Contents Introduction 1 Safety Instructions 2 Installation Instructions 3 Electrical General 4 Control Panel Identification 5 Start Up Preparations 6 Changing the Filter Cycles 7 Trouble Shooting 7 8 Spa Maintenance 9 10 Jets Valves Injectors Suction 11 Warranties 12 Safety Precautions 13 Registration Card 13 ...

Страница 3: ...ating a Lifestyle that Lasts a Lifetime With proper care operation and maintenance your spa will provide your family many years of comfort and pleasure Please take time to read all the instructions before you install your Strong Pools Spa Cyprus spa This manual explains safety precautions installation instructions operating directions and maintenance procedures If you have any questions after read...

Страница 4: ...d 40 C 104 F and lower water temperature is recommended for extended use exceeding 10 15 minutes and for young children Long exposure at higher temperature can result in dizziness and or hyperthermia Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98 F 36 7 C The symptoms of hyper thermia include dizziness fainting ...

Страница 5: ...oom location landscaping and evening lighting The spa with water is very heavy if the spa is placed on flooring or decking be sure the structure is strong enough to support the weight The necessary support should be at least 75 pounds per square foot Install your spa in a way that will allow easy access to the equipment door Storage area for maintenance equipment and chemicals storing chemicals in...

Страница 6: ...ctrical codes in effect at the time of installation The circuit breaker must be dedicated and cannot be shared with any other appliances It should be labeled and easily accessible to users DO NOT USE EXTENSION OR PLUG TYPE CORDS OF ANY KIND The use of a shut off box near the spa is recommended Metal surfaces within 5 feet of the spa must be grounded to the spa A 120 Volt 15 Amp GFI rated plug is f...

Страница 7: ...ped with an LED Multi Color Light The colors will cycle as you press the light button on and off HEAT Press the Heat key to adjust the temperature Press once and hold will raise tem perature Press a second time and hold will lower temperature to the minimum set point of 70º F or 21º C A red LED will flash at the topside control when the heater is on There are FOUR unions that may require hand tigh...

Страница 8: ...l operation to protect the system Upon power up the read out will display three digit software release This number will then change to 888 while the system is booting up After starting up the low speed pump will start running if the water temperature is below 100 F 37 8 C If a FL1 appears on the display turn the system off and repeat step 2 If the water temperature is below 55 F 12 8 C ICE will al...

Страница 9: ...f the optional secondary pump blower circuit This secondary circuit will automatically shut off in 30 min if left on No display at topside Check that connection to main board is clean and sound at J8 Test a new topside control Check for 120V primary power going into the transformer and for 12V secondary power out of the trans former to J6 and J7 on the board before replacing the transformer Relace...

Страница 10: ...opside control remove clean reconnect Try new topside control Replace main board Pump s blower or light does not shut off Try new topside control Replace main board Circulation pump does not work Check the fuse and power connections Light does not work Press Light to turn the light on off The Antigua Spa is equipped with an LED Multi Color Light The colors will cycle as you press the light button ...

Страница 11: ...pment Since the water capacity of your spa is far less than that of a swimming pool the chemical reaction caused by the presence of one or more persons in the spa is more rapid and pro nounced In other words it is much more difficult to maintain the proper pH balance in a spa than in a swimming pool For these reasons it is important to check frequently the total alka linity of the water the pH lev...

Страница 12: ...y compati ble with the other chemicals listed Use as recommended by the manufacturer SPA WATER should be changed periodically depending upon frequency of use and other conditions that may affect water suitability Typically 60 to 90 days is a satisfactory interval under normal conditions With heavy usage the interval between water changing should be less SPA FILTER CARTRIDGE should be cleaned every...

Страница 13: ...ctional Jet 3 Center Pivots Top Air Control Valve Air Control Valve should be turned off when spa is not in use The spa will heat up faster Bottom Suction Turn counter cloc k w i s e t o o p e n Turn counter cloc k w i s e t o o p e n Turn counter cloc k w i s e t o o p e n ...

Страница 14: ...ue to obvious misuse NOTE the warranty begins from the date of delivery and is only valid to the original owner The warranty does not cover damage caused by neglect misuse improper hookup and water chemistry or leaving the empty spa exposed to the sun Pressure Switch adjustments are cov ered for thirty 30 days from delivery Travel or mileage costs are not covered under these warranties and may be ...

Страница 15: ...Tub when others are present 2 Children should be supervised at all times 3 To avoid the risk of drowning keep the filter clean and unclogged Do not remove the suction drain cover Do not modify the suction or filtration systems 4 Exercise caution when entering or leaving the Hot Tub When changing positions be sure of your footing before applying your full weight as water refraction can be misleadin...

Страница 16: ...NDAY THROUGH FRIDAY 8 30 AM 5 00 PM E S T 570 275 2700 GIVE YOUR NAME TELEPHONE NUMBER AREA CODE NAME OF SPA NAME OF MODEL QUANTITY AND TYPE OF PARTS REASON FOR REQUEST A DAMAGED B DEFECTIVE PLACE STAMP HERE STRONG POOLS SPAS 3204 Point Township Drive Rte 11 P O Box 108 Northumberland PA 17857 ...

Отзывы: