INSTALLATION / OPERATION
Before you start with the installation take care that no audio parts are connected with the
Stromtank and the unit is not connected with the electric circuit.
To install the Stromtank and connect it with your audio equipment please follow the steps in
order.
1. Make sure that the position of the main switch at the rear is in “off” position and the push
button at the front is released.
2. Connect the AC input with a power cord to the next available grid outlet (115 Vac* outlet).
ATTENTION:
Never connect the Stromtank’s AC input with its AC outlets. This will cause
damage to the unit!
3. Insert the supplied key into the key switch, turn it into a vertical position and remove the
key from the switch.
4. Push the main switch at the rear in “on” position. Now the ampere meter at the front is
illuminated by a blue light (front button below the instrument must be in “off” position –
button should not be pressed).
5. Plug your audio AC cords into the AC outlets. It is important to make certain that all audio
units are in “off” position.
6. Switch on both fuse switches above the AC outlets.**
7. Turn on your connected audio equipment.
ATTENTION:
One after the other!
8. To select pure power off-grid mode and enjoy distortion free music push the front button
and the blue light will change to a green illumination. Or go to grid mode (front button
released, blue light) for charging and on-grid music listening.
*
ATTENTION:
Version for Japan and Taiwan: 100 V. European version: 230 V.
** European version: one fuse switch only.
Turn on your audio system. To hear the best quality of your audio components it is recom-
mended to start with off-grid mode. This allows the Stromtank to warm-up and shakedown
the system.
REAR PANEL US
thermal magnetic fuses fuse (10A slow blowing)
CAN bus
power indicator
USB data output
main switch on/off
emergency charge input
lock
AC outlets
ground terminal
AC input
1
2
1
3
4
5
5
5
5
6
7
8
9
11
10
1
2
3
4
5
6
7
8
9
10
11
1
2
3
4
5
6
7
8
9
10
11
1
3
1
4
5
2
6
7
8
9
11
10
1
REAR PANEL EU
AC outlets AC input
thermal magnetic fuse
power indicator
CAN bus
main switch on/off
USB data output
lock
emergency charge input
ground terminal
fuse (10A slow blowing)
9
8
Содержание S 5000
Страница 1: ......
Страница 11: ...Made in Germany 2016 stromtank com All rights reserved 20 ...