DESCRIPTION
PAGE 6
It is important to read and understand this manual before using the STROCO heater to ensure
optimum utility and safety. Please mail the warranty card to STROCO ApS.
The presence of the above-mentioned basic elements, in the right quantities and correct mixtures, is
essential to the heat production of the STROCO heater.
In case of failure or unsatisfactory operation, make sure to check these basic elements first.
The STROCO heater is independent of the operation of the vehicle’s engine, and vice versa. This
means that interruptions in one system do not affect the operation of the other. However, lack of
electrical power or fuel will affect both systems, if both engine and heater are connected to the same
battery and fuel tank.
The fuel-burning heater’s job is to heat the water in the heating system. It does this by burning fuel
at a high temperature in the combustion chamber. This heat is transferred to the water in the boiler
section of the heater, and the water is pumped into the heat exchanger units in a continual process,
where the hot water acts as a transfer agent between heat production (the heater) and heat
exchangers.
The heart of the heater is the combustion section. Fuel is pumped to here and vaporized by a nozzle.
This fuel vapour ignites, establishing a flame (combustion). One of the factors that ensure correct
combustion of the fuel vapour is regulation of air intake. The combustion process and other function-
ality of the heater is controlled by the brain of the system: the electronic control and monitoring unit.
This automatic system ensures that the process follows predetermined routines. If the process should
deviate from these routines, or if the combustion process fails or becomes deficient due to poor
supply of the basic elements - fuel, water, and air - the system shuts down the process. In theory, the
presence of the basic elements alone should ensure the combustion process, but since we require the
process to be highly efficient and reliable, it must run in a controlled manner. This manual will help
you to keep the heater running satisfactorily at all times. What to do if the heater is not working, or
performs inadequately?
The section Alarm Functionality can help you to locate the source of an error and analyse the
symptoms.
The section Error Remedy Instructions in the Description of Functionality explains and illustrates
remedial actions.
Heat
Fuel
Water
Electrical power
Air
+
=
Содержание 35.02 M
Страница 2: ......
Страница 8: ...BUILT IN DIMENSIONS PAGE 8 All measurements 2 mm...
Страница 13: ...PAGE 13 Plug B Plug R Front Back...
Страница 32: ...ASSEMBLY DRAWING PAGE 32 73...
Страница 34: ...ASSEMBLY DRAWING PAGE 34...
Страница 38: ...LABELS STROCO 35 02 M EL PAGE 38 The heater is labelled with a model plate and warning label as shown below...