Lever (1) (Fig. 15) on which the cylinder hangs must be set so that there is a
free space of at least 0.5 to 1 mm between piston rod and eccentric (2) (Fig.
15). Secure lever (1) (Fig. 15) in this position on the eccentric with both
threaded screws.
Fig. 15
The plunger should travel a plunger path of at least 3.8 mm by adjusting the
scale.