INSTALATION AND REMARK:
…………………………………………………………………………………………………………………….
1. Before installation, must carefully check whether there are some parts damaged during Transport and
stock. For example, whether the cable and plug are in good condition, and the insulated resistance is
above 0.5Mft, otherwise must check the fault.
2. Check whether the power supply is conformed to the stipulation of nameplate before installation.
Pump must connect with earth to keep safe.
3. Before installation, must check whether the cable and plug is fracted, scratched, broken, etc. If they are
faulty, must consult dealer or technician qualified to replace them.
4. Using iron thread or hoop to make the outlet and discharge pipe tight, and then tie a rope on the
handle as sling so as to move the pump up and down.