To get the most out of your new fan heater, please read through these instructions and the attached safety
regulations before use. Please also save the instructions in case you need to remind yourself of the fan
heater’s functions at a later date.
TECHNICAL SPECIFICATIONS
Voltage/frequency
230 V / 50 Hz
Power rating
2000 W
Settings
3 (650 W, 1300 W and 2000 W)
Temperature
Continuously adjustable 0-
85 °C
Dimension
197x210x303mm
Weight
4.2 kg
Air displacement
152 m
3
/h
Cable length
1,5 m
Protection class
IP24
- Requires at least a 10 A fuse
- Housing of steel plate and heat-resistant lacquer
THE FAN HEATER DIALS
1. Function selector with three power settings
2. Thermostat dial
THERMOSTAT INSTRUCTIONS
- At first turn the thermostat to “Max” and let the heater operate with full power input. When the room
temperature reaches the required value, turn the thermostat to left until it switches off.
- The thermostat will then switch on and off automatic to control the room temperature according to the preset
value and keep the room temperature constant.
- When using the heater for the first time, you may notice a slight emission of smoke. This is quite normal and it
stops after a short time. The heating element is made of steel and was coated with a layer of protection oil by
production. The smoke is caused by the left oil when heated.
SPECIAL SAFETY REGULATIONS
- The fan heater is not suitable for use outdoors in damp weather, in bathrooms or in other wet or damp
environments.
- Please note that the fan heater can become very hot and should, therefore, be placed at a safe distance from
flammable objects such as furniture, curtains and similar.
- Do not cover the fan heater.
- Do not place the fan heater immediately under a wall socket.
- Do not connect the fan heater using an on/off timer or other equipment which can automatically switch the