background image

After Use

After you have finished using the inverter (or when the inverter is not in use), turn off the unit and 
make sure your vehicle’s fully switched off. 
Then, turn the unit off and then disconnect the inverter from the 12V power supply. When discon-
necting from the battery, disconnect the negative cable first, followed by the positive cable.

Best Practices for Protecting Your 12V Battery

• 

To prevent your vehicle’s 12V battery from being depleted. We recommend running the engine for 10 to 
20 minute to recharge the battery after using the inverter for 2 to 3 hours. Important: Before starting your 
vehicle’s engine, please disconnect the inverter from your battery/power supply.

• 

When connecting the inverter to your battery’s terminals, it is important that you connect it via the correct 
polarity (i.e. C from inverter to + of battery terminal and connect – from inverter to – of battery 
terminal) to prevent reverse polarity.

• 

When you are using the inverter and you hear a beeping sound coming from the inverter, this means your 12V 
battery is low. To recharge, disconnect the inverter from your battery and turn on the engine for 2 to 3 hours.

• 

When charging your 12V battery using a battery charger, please disconnect the inverter.

Measuring The AC Voltage

Safety Features

The output waveform of the AC output is a MODIFIED SINE WAVE. To measure the AC 
output voltage, you must have a TRUE RMS VOLTMETER. 

Feature

Explanation

Anodized Aluminium Casing

Prevents corrosion & wear. The case effectively 
protects the inverter’s interior elements.

Low Battery Alarm

Sounds when your 12V battery is low. To 
resolve, disconnect the inverter from battery/
power supply and recharge the battery. 

Built-in Cooling Fan

The built-in cooling helps to prevent overheating 
during use. 

Overheat Protection

After prolonged use (more than 2 to 3 hours), 
the inverter will generate heat. This is not a 
malfunction of the built-in cooling fan. However, 
if the inverter does overheat, after prolonged 
use, the unit will automatically shut off for it to 
cool down.

Overload/Short Circuit Protection

The inverter automatically turns itself off if the 
connected load is too high or if it too low

Thermal Protection

The inverter’s thermal protection feature pre-
vents it from operating when its temperature 
exceeds 60+/-5 °C

Содержание SWINV2000

Страница 1: ...Information for use SWINV2000 4000W PEAK 2000W Inverter Modified Sine Wave ...

Страница 2: ...This inverter is only designed to accept a DC power supply Warning Heated Surface 6 The inverter s outer casing may become hot after prolonged use or overloading During operation ensure there is atleast a 5cm 2 inches gap between the inverter and any other walls 7 Please keep any flammable materials away from the inverter during operation Warning Explosion Hazard 8 Never use the inverter in the pr...

Страница 3: ...h connections Most computers laptops photocopiers cordless power tools and plastic cased appliances are identified as Class 2 appliances Class 1 appliances on the other hand are protected by basic insulation and earthing provision and most typically come in a metal casing This product is not suitable for operating Class 1 appliances Typical Class 1 appliances include toasters kettles washing machi...

Страница 4: ...sine wave inverters provide even flow of electric output where a modified sine wave inverter is staggered The figure below shows a graphical comparison of modified sine wave inverters and pure sine wave inverters Modified Sine Wave Sine Wave Optimum Working Conditions For safe optimum performance please install the inverter in a location that is Dry The inverter should not be near any liquid or mo...

Страница 5: ... and then connect the clamp to the positive battery terminal of your 12V battery IMPORTANT When starting your vehicle s engine please disconnect the inverter first before starting the engine Operating Appliances Operating an Appliance Through The 3 Pin Plug Once the inverter is connected to your battery just plug in your appliance via the 3 pin socket and then turn ON the power switch Operating an...

Страница 6: ...y is low To recharge disconnect the inverter from your battery and turn on the engine for 2 to 3 hours When charging your 12V battery using a battery charger please disconnect the inverter Measuring The AC Voltage Safety Features The output waveform of the AC output is a MODIFIED SINE WAVE To measure the AC output voltage you must have a TRUE RMS VOLTMETER Feature Explanation Anodized Aluminium Ca...

Страница 7: ...e out the fuse Fig 1 Troubleshooting What To Do When The Inverter Is Not Working Troubleshoot Problem Possible Cause Suggested Solution No AC out the green LED light is not coming on DC input is below 10V Recharge or replace the battery No AC output the inverter is cold Poor connection with the battery Switch off vehicle discon nect inverter from battery Then reconnect the inverter to the battery ...

Страница 8: ...t Waveform USB output No load current Battery low shutdown Battery low alarm Thermal shutdown Fuse Product dimensions Streetwize 2000W Modified Sine Wave Inverter 2000W 4000W 230V AC 12V 10 to 15V DC Modified Sine Wave 5V DC 1000mA 0 3A 10 0 5V DC 11 0 5V DC 60 5 C 30A x 8 41 x 19 2 x 10CM Streetwize Ashburton Road West Trafford Park Manchester M17 1RY www streetwizeaccessories com EU Regd Address...

Отзывы: