Installation Instructions Strebel Q-boiler range
38
installation example
figure 17
17.2
Radiator installation with underfloor heating zone
A Boiler:
A0
Connection terminal Strebel Q-boiler
A4
Outside sensor
ARV12
A9
MadQ zone controller
23BC
A10
Connection terminal MadQ built in
B Cylinder:
B3
Cylinder sensor
B5
Three-way valve cylinder
C Direct zone:
C6
Pump direct zone
D Mixing zone:
D2
Flow sensor mixing zone
D5
Three way valve mixing zone
230V~
D6
Pump mixing zone
See also the installation manual MadQ Zone controller.