50
User Level Key within Table:
•
E = End User.
•
I = Commissioning.
•
F = Heating Engineer.
•
O = Expert Level
The below table lists room and operator unit parameters
Operating Line (one-up)
User Level
Function [value range]
Standard
Min
Max
Unit
Time of Day and Date
1
E
Time
01:00
00:00
23:59
hh:mm
2
E
Date
01.01.2030
01.01.2004
31.12.2099
dd.mm.
y yyy
5
F
Start of summertime
25.03
01.01
31.12
dd.mm
6
F
End of summertime
25.10
01.01
31.12
dd.mm
Operator section
20
E
Language
German ¦ English ¦ French ¦ Italian ¦.
German
-
39
O
Commissioning menu
Off ¦ On
On
-
40
I
Used as
Room unit 1 ¦ Room unit 2 ¦ Room unit 3 ¦ Operator unit
1 ¦ Operator unit 2 ¦ Operator unit 3
Room unit 1
-
42
I
Assignment device 1
Zone 1 ¦ Zone 1 and 2 ¦ Zone 1 and 3 ¦ All zones
Zone 1
-
44
I
Operation zone 2
Jointly with zone 1 ¦ Independently
Jointly with zone 1
-
46
I
Operation zone 3
Jointly with zone 1 ¦ Independently
Jointly with zone 1
-
47
I
Room values device 1
Zone 1 only ¦ For all assigned zones
For all assigned zones
-
48
I
Warmer device 1
None ¦ Zone 1 only ¦ For all assigned zones
For all assigned zones
-
50
I
Room temperature
0
50
°C
51
I
Room temperature min
0
50
°C
52
I
Room temperature max
0
50
°C
54
F
Readjustment room sensor (Temperature).
0.0
-3.0
+3.0
°C
55
I
Room humidity
0
100
%
59
F
Readjustment room sensor (Humidity).
0
-20
+20
%
70
F
Software version
-
17.7.1
T
IME OF
D
AY AND
D
ATE
The controller has a yearly clock with time of day, weekday and date.
No.
Operating line
Settings
1
Time
2
Date
5
Start of summertime
6
End of summertime
Daylight saving time / Standard time changeover: The dates set for the changeover to Summer or Winter time
ensure that on the first Sunday after the set date, the time of day will change from 02.00 (Winter time) to 03.00
(Summer time) and vice versa. If the entered date is on a Sunday, then it changes over on a Sunday.