PZ0064
www.securitycamera2000.com
30
If switch/alarm/log/lock all set as ON, When sensor triggered, it will trigger alarm signal and event
log, it will also trigger alarm recording and event recording, besides, the EVENT LOG can’t be
deleted even HDD-formatted or overwrite.
and it will also display in live view, Please press
【
Enter
】
into the soft keyboard. The label also
identifies the type of event when doing a quick search using
EVENT SEARCH
option.
SET:
LOW (normal close) means high to low trigger alarm.
HIGH (normal open) means low to high trigger alarm.
ALARM:
Press ENTER to select between OFF or ON:
ON means when sensor triggered, alarm LED will flashing, until re-login the system with account, the
flashing will disappear, also, if the security set as OFF, I.E no need enter password to re-login, just
pressing ENTER can disappear the flashing.
LOG:
Press ENTER to select YES/NO to enable or disable the input sensor to put as event log file, the
EVENT LOG is recorded in EVENT search file e.g.: If set as ON, using
EVENT SEARCH
option even
sensor triggered, there is event file on this menu.
LOCK:
To enable the event does not erase during the over-write process of hard disk;
NEXT PAGE:
Sensor trigger action means setup the alarm linkage for each sensor, for example, you setup the
ch1 as the alarm linkage for sensor1, when sensor1 triggered, ch1 will change to full screen. And the device will
response the trigger by PRI, sensor1 is highest, sensor8 is lowest.
B)
SPEED
Setup the alarm for over speed and some other parameters.