ISTM-ALL MDVR-2012_Q2_Ver 1.0
21/27
1.3
Accessories Testing
1)
Camera testing
After the MDVR gets power and works fine. Please try to test the camera as following:
(
1
)
Checking the video interference exists or not firstly.
(
2
)
Angle and focus adjustment and turning the Lens circle to adjust the focal length for a
clearer image according to the scope of monitoring.
(
3
)
For the night vision camera, please check its infrared light is on or not in dark environment, off in
bright environment. (Please try to manually cover and release the CCD on the camera lens for testing)
(
4
)
Recording the video and playback locally to check the image quality. If the video image
is not good enough please try to change another camera.
2)
Monitor Testing
Please Set up suitable brightness and contrast to check the monitor working status including full screen, image
quality or or interference. Meanwhile Please avoid the reflect light to the driver’s view.
1.4
MDVR Recording and Network Testing
1.4 1
MDVR Recording Testing
a)
Ignition recording: Active the ignition recording function and check whether MDVR can record as scheduled. In a
given time(10 minutes), shut down and check the machine off or not.(for post recording of 1-300 mins in Ignition
video, it is better to test 1 min post recording. When the working time no more than 10 mins, the machine will
delay 5min to shut down)
b)
Time recording: setting up the time like 10mins, please check whether the MDVR machine can boot up and start
recording in a given time and can turn off and stop recording after 10 minutes.
c)
Ignition recording and time shut down: Setting a shut down time, ignite the machine to check the machine shut
down when time is up. Checking the video file.
d)
Alarm Video. Starting video when trigger from internal factor and external factors, like door- open alarm video,
when the vehicle door is open, the machine will start to video when receiving the door-open signal.
Diagram for power connection to video machine from Ignition
For the details please check the MDVR GUI manual.
1.4.2
I/O Sensor Testing
Please enter into the MDVR GUI and select the function “Sensor” (Setup
Event
Sensor). Select "ON“ or “OFF” for enable