General Information
Model Number:
Replacement Filter Type:
Approximate Filter Capacity:
Approximate Flow Rate at 60 psi:
Housing Composition:
Rubber Items:
Inlet:
Outlet:
Maximum Working Pressure:
Minimum Working Pressure:
Maximum Operating Temperature:
Minimum Operating Temperature:
Particle Retention Size:
Certified by:
Stream Flow Plus (FP1)
Stream Flow Plus Cartridge Part (FC1)
750 gallons
0.75 gpm
Stainless Steel
Nitrile
1/4” NPTF x 1/4” tube
1/4” NPTF x 1/4” tube
100 psi / 8.8 kg/cm
2
30 psi / 2.1 kg/cm
2
100˚F / 38˚C for cold water use only
32˚F / 0˚C for cold water use only
sub micron (0.5 micron)
NSF International , CA Dept. of Public Health : Cert: #13-2190
1. The Stream Flow Plus Drinking Water System is installed
below the sink and connects to a separate faucet included in the
installation materials.
2. Replacement filters can be purchased at StreamFilters.com.
Filter life will vary in proportion to the amount of water used and
the level of impurities in the water being processed.
Replace the filter cartridge when the first of the following occurs:
(a) annually; (b) when the system’s rated capacity is reached;
(c) the flow rate diminishes; or (d) the filter becomes saturated
with bad tastes and odors. The rated capacity of the filter
cartridges is shown above.
3. This system is not intended to be used where the water is
microbiologically unsafe or with water of unknown quality without
adequate disinfection before or after the unit. Systems certified
for cyst reduction may be used on disinfected waters that may
contain filterable cysts.
4. Do not allow water to freeze in the unit. If unit is exposed to
freezing temperatures, drain water from unit and remove filter.
5. Do not allow water to sit in unit for extended periods of time
(10 or more days) without being used. If unit is to be left unused
for more than 10 days, drain all water from the system and remove
the filter. Upon your return, reconnect the filter in the housing and
continue use. In the event water does sit in the unit for 10 or more
days, the system should be flushed by allowing water to flow to
waste for about 3 minutes; then continue use as normal.
6. To dispose of the used filter, remove it from the housing and
place the old filter in your normal refuse.
Notes
A. Operation & Maintenance Specifications
3
General Information
A-130317
01
Sec.