Service and maintenance
Sherpa 120, 140 | 06.19
169
9.15.6 Clean ventilation filter
WARNING
Machine movements
Unintentional movements of the machine or its working tools
may cause serious injuries.
•
Secure the machine against accidental starting and
rolling.
Operative staff:
•
Operator
1.
WARNING
– Increased risk of accident when
working at high levels. Ensure working conditions
enabling safe working. Open the service cover (1).
2. Use a cloth to thoroughly clean the area surrounding the
filler neck.
Fig. 124
3. Unscrew the cap (1).
4. Unscrew the screws (2).
5. Pull the ventilation filter out.
6. Release the safety chain.
7.
CAUTION
– Risk of injury to the eyes due to flying
particles. Wear protective goggles. Use a cleaning spray
or compressed air to clean the ventilation filter.
8. Fix the ventilation filter at the safety chain.
9. Use the screws (2) to tightly screw on the ventilation filter.
10. Regularly check the contamination indicator (3) for the
hydraulic filter.
–
green = normal condition
–
red = contaminated; replace filter (authorised
workshop)
11. Tightly screw on the cap (1).
12. Close the service cover.
Fig. 125