background image

6. Related Documentation 

The following sections contain related information pertaining to ftServer T30 systems. 

6.1 Service Documentation 

 

ftServer Technical Service Guide 

6.2 Customer Documentation 

 

Stratus ftServer T30: Site Planning Guide (

R001L)

 

 

Stratus ftServer T30: Installation Guide (

R002L)

 

 

Stratus ftLinux System Administrator’s Guide (

R003L)

 

 

Stratus ftServer T30: Operation and Maintenance Guide (

R004L)

 

 

Release Notes: Stratus ftLinux Release 2.1 (

R005L)

 

 

Read Me First: Unpacking an ftServer T30 System (

R006L)

 

 

Stratus ftServer: ActiveService Network Configuration Guide (

R013W)

 

 

Stratus ftServer T30 with ftLinux Release 2.1: Stratus ftLinux Migration White Paper, 
Stratus ftServer T30 Configuration Specification (

R1000LCD)

 

 
 
 

Содержание ftServer T30

Страница 1: ...pendent of a cabinet 2 Operating System Requirements The ftServer T30 system is supported by the Stratus ft Linux operating system which is based on the Linux operating system with Stratus additions T...

Страница 2: ...al Inline Memory Module DIMM memory in 256 MB and 512 MB configurations The minimum ftServer T30 logical memory is 512 MB and the maximum is 3 GB Up to six DIMMs can be housed in each CPU enclosure DI...

Страница 3: ...n Min Max U574 2 port 1000Base Sx Fiber Gigabit Ethernet Adapter 0 4 U575 2 port 1000Base T Copper Gigabit Ethernet Adapter 0 4 U917 VGA Adapter 2 2 U918 4 port T1 E1 Adapter For SINAP 0 4 3 2 2 SCSI...

Страница 4: ...oppy Disk Drive Modem 3 5 1 Tape Drives ftServer T30 systems support DDS 4 tabletop tape drives No tape drives are mounted in the cabinet They are all external to the cabinet The following table lists...

Страница 5: ...a a USB port 3 5 4 Modem The C719 an external serial 56K Data Fax MultiTech ZBA modem is used to connect to the Stratus ActiveService Network ASN 4 System Configuration Marketing ID P5101R 2D Processo...

Страница 6: ...40 C to 70 C Unvented 40 C to 60 C Vented Operating Altitude 0 to 10000 ft 0 to 3048 m Maximum rate of temp change during operation 12 C Hour Relative humidity during operation 5 to 85 Non condensing...

Страница 7: ...ical Height 1 75 in 4 45 cm 1U Width 19 in 48 3 cm Depth 24 in 61 cm Environmental Operating temperature 32 F to 104 F 0 C to 40 C Storage temperature 13 F to 140 F 25 C to 60 C Relative humidity duri...

Страница 8: ...35 C Storage temperature 41 F to 113 F 5 C to 45 C Relative humidity during operation 30 to 80 noncondensing Relative humidity during storage 5 to 90 noncondensing Heat dissipation 103 BTUs per hour...

Страница 9: ...Nominal input voltage Frequency 100 240 volts AC 50 60 Hz Physical Height 3 7 in 95 mm Width 4 6 in 116 mm Depth 8 7 in 220 mm Weight 4 6 lb 2 1 kg 5 7 T512 DDS 4 DAT Tape Drive with Autoloader Power...

Страница 10: ...Server T30 Installation Guide R002L Stratus ftLinux System Administrator s Guide R003L Stratus ftServer T30 Operation and Maintenance Guide R004L Release Notes Stratus ftLinux Release 2 1 R005L Read M...

Отзывы: