STRATOS S210-X22RQ Скачать руководство пользователя страница 41

R

EGULATORY

 

AND

 C

OMPLIANCE

 I

NFORMATION

R

ESTRICTION

 

OF

 H

AZARDOUS

 S

UBSTANCES

 (R

O

HS) C

OMPLIANCE

 

4

-5

modem telecommunication circuitry must be UL listed. In 
addition, the modem must have the appropriate telecom-
munications, safety, and EMC approvals for the region in 
which it is sold.

Peripheral Storage Devices: must be UL recognized or UL 
listed accessory and TUV or VDE licensed. Maximum 
power rating of any one device is 19 watts. Total server 
configuration is not to exceed the maximum loading condi-
tions of the power supply.

Restriction of Hazardous Substances 

(RoHS) Compliance

Quanta® Computer Inc. has a system in place to restrict the 
use of banned substances in accordance with the European 
Directive 2002/95/EC. Compliance is based on declaration that 
materials banned in the RoHS Directive are either (1) below all 
applicable threshold limits or (2) an approved / pending RoHS 
exemption applies.

RoHS implementation details are not fully defined and may 
change.

Threshold limits and banned substances are noted below:

Quantity limit of 0.1% by mass (1000 PPM) for:

Lead

Mercury

Hexavalent Chromium

Polybrominated Biphenyls Diphenyl Ethers (PBDE)

Quantity limit of 0.01% by mass (100 PPM) for:

Cadmium

End of Life / Product Recycling

Product recycling and end-of-life take-back systems and 
requirements vary by country. Contact the retailer or distributor 
of this product for information about product recycling and / or 
take-back.

Содержание S210-X22RQ

Страница 1: ...Version 1 0 STRATOS S210 Series S210 X22RQ Two Socket High Memory 2U Rackmount Server 8VHU V Guide...

Страница 2: ...denotes keyboard keys WARNING Warning information appears before the text it references and should not be ignored as the content may prevent damage to the device CAUTION CAUTIONS APPEAR BEFORE THE TE...

Страница 3: ...AT compatible region of battery backed 128 bytes of mem ory which normally resides on the baseboard CPU Central Processing Unit Deasserted A signal is deasserted when in the inactive state Active low...

Страница 4: ...y Ms Milliseconds Mux Multiplexer NIC Network Interface Card NMI Nonmaskable Interrupt NM Node Management OBF Output buffer OEM Original Equipment Manufacturer Ohm Unit of electrical resistance PDB Po...

Страница 5: ...rver Management Interrupt SMI is the highest priority nonmaskable interrupt SMM Server Management Mode SMS Server Management Software SNMP Simple Network Management Protocol SOL Serial Over LAN UART U...

Страница 6: ...ystems networks and modems attached to the server before opening it Otherwise personal injury or equipment damage can result Electrostatic discharge ESD and ESD protection ESD can damage drives boards...

Страница 7: ...SAFETY INFORMATION to grip with but not squeeze the pliers or other tool used to remove a jumper or the pins on the board may bend or break...

Страница 8: ...this document is subject to change without notice The manufacturer makes no representations or warran ties with respect to the contents hereof and specifically dis claims any implied warranties of me...

Страница 9: ...About the Server Chapter 1...

Страница 10: ...rofile riser slot optional or 2 PCIe x8 G3 low profile riser slots optional 4 PCI x8 G3 low profile riser slots and 1 PCIe x4 G3 low profile riser slot 1 PCIe x8 G3 Network Mezzaine card slot and 1 PC...

Страница 11: ...AS 2108 Mezzanine card optional Quanta LSISAS 2208 Mezzanine card optional Quanta LSISAS 2308 Mezzanine card optional System Memory 24 DDR3 800 1066 1333 1600 1866 MHz ECC RDIMM LR DIMM slots up to 76...

Страница 12: ...8 PD 32 mezzanine card LSI RAID 6 Key for RAID 0 1 10 5 6 50 60 optional Quanta LSISAS2208 PD 32 mezzanine card for RAID 0 1 10 5 optional Quanta LSISAS2208 PD 32 mezzanine card LSI RAID 6 Key for RAI...

Страница 13: ...CKAGE CONTENTS 1 4 Package Contents The following list includes the package components 1 2U chassis system 2 Processor heat sinks 1 2 Power supplys Optional 1 2 Power cords Optional 1 CD user manual i...

Страница 14: ...16 G3 low profile riser slot or 1 PCIe x8 G3 low profile riser slots 1 PCI x8 G3 low profile riser slots and 1 PCIe x4 G3 low profile riser slots 2 PCIe x8 G3 low Profile riser slots and 1 PCIe x4 G3...

Страница 15: ...s 1 PCI x8 G3 low profile riser slots and 1 PCIe x4 G3 low profile riser slots 2 PCIe x8 G3 low Profile riser slots and 1 PCIe x4 G3 low profile riser slots 1 PCIe x8 G3 10GbE SFP Mezzaine card slot a...

Страница 16: ...S 1 7 System Front Features 3 5 HDD System Front Features Figure 1 3 3 5 HDD System Front Features 2 1 Table 1 2 3 5 HDD System Component Description NO ITEM DESCRIPTION 1 Front control panel Node con...

Страница 17: ...ONT FEATURES 1 8 2 5 HDD System Front Features Figure 1 4 2 5 HDD System Front Features 2 1 Table 1 3 2 5 HDD System Component Description NO ITEM DESCRIPTION 1 Front control panel Node control system...

Страница 18: ...Lights for system identification 6 Power Button Based on System Off Push Button to PSU and System on Based on System Off Push Button to PSU and System off 7 Identification Button Push to activate ID...

Страница 19: ...rip OFF SEL Cleared DC Off Last pending warning or error has been de asserted HDD Activ ity Green Blinking Hard disk drive access only on board SATA port OFF No access non SAS LAN1 LED Green ON Link G...

Страница 20: ...power supply unit Left PSU1 Right PSU0 2 PSU Connector Insert power supply cord 3 ID LED Lights for system identification 4 VGA port Connect a monitor to this port 5 Console port 6 USB port USB ports...

Страница 21: ...ec OFF OFF link speed is 10Mbits sec LAN2 LED left Link Act Green ON LAN Link Green Black Blinking LAN Access off when there is traffic OFF Disconnect Speed Green ON Green link speed is 1000Mbits sec...

Страница 22: ...Installation and Assembly Safety Instructions Chapter 2...

Страница 23: ...ied AC power cord if it is not the exact type required A product with more than one power supply will have a separate AC power cord for each supply The power button on the system does not turn off sys...

Страница 24: ...ge ESD protection by wearing an antistatic wrist strap attached to chassis ground of the system any unpainted metal surface when handling compo nents 6 Do not operate the system with the chassis cover...

Страница 25: ...heck that cables add in cards and other components are properly installed 3 Attach the covers to the chassis with the screws removed earlier and tighten them firmly 4 Insert and lock the padlock to th...

Страница 26: ...o a surge suppressor and disconnect telecommunication lines to your modem during an electrical storm Provided with a properly grounded wall outlet Provided with sufficient space to access the power su...

Страница 27: ...Safety Information Chapter 3...

Страница 28: ...omponents will void the UL List ing and other regulatory approvals of the product and may result in noncompliance with product regulations in the region s in which the product is sold Safety Warnings...

Страница 29: ...lines to your modem during an electrical storm Provided with a properly grounded wall outlet Provided with sufficient space to access the power supply cord s because they serve as the product s main...

Страница 30: ...ADD OR REMOVE ANY NON HOT PLUG COMPONENTS CAUTION DO NOT ATTEMPT TO MODIFY OR USE AN AC POWER CORD IF IT IS NOT THE EXACT TYPE REQUIRED A SEPARATE AC CORD IS REQUIRED FOR EACH SYSTEM POWER SUPPLY CAU...

Страница 31: ...INTO SOCKET OUTLET S THAT IS ARE PROVIDED WITH A SUITABLE EARTH GROUND CAUTION TO AVOID PERSONAL INJURY OR PROPERTY DAMAGE THE FOL LOWING SAFETY INSTRUCTIONS APPLY WHENEVER ACCESSING THE INSIDE OF THE...

Страница 32: ...e entire unit not just to the server s To avoid risk of potential electric shock a proper safety ground must be implemented for the rack and each piece of equipment installed in it Elevated Operating...

Страница 33: ...le Earthing Reliable earthing of rack mounted equip ment should be maintained Particular attention should be given to supply connections other than direct connections to the branch circuit e g use of...

Страница 34: ...CAUTION DO NOT ATTEMPT TO DISASSEMBLE PUNCTURE OR OTHERWISE DAMAGE A BATTERY CAUTION CAREFULLY ROUTE CABLES AS DIRECTED TO MINIMIZE AIRFLOW BLOCKAGE AND COOLING PROBLEMS FOR PROPER COOLING AND AIRFLOW...

Страница 35: ...ified and rated Laser Class I for Optical Transceiver product CAUTION TO AVOID RISK OF RADIATION EXPOSURE AND OR PERSONAL INJURY Do not open the enclosure of any laser peripheral or device Laser perip...

Страница 36: ...Regulatory and Compliance Information Chapter 4...

Страница 37: ...sting Marks USA Canada CE Mark Europe FCC Marking Class A USA This device complies with Part 15 of the FCC Rules Operation of this device is subject to the follow ing two conditions 1 This device may...

Страница 38: ...2 GOST R Marking Russia ICES Canada This Class A digital appara tus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme la norme NMB 003 du Can ada Recycling Pack age Ma...

Страница 39: ...d on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the...

Страница 40: ...mmission KCC Class A State ment Regulated Specified Components To maintain the UL listing and compliance to other regulatory certifications and or declarations the following regulated com ponents must...

Страница 41: ...m in place to restrict the use of banned substances in accordance with the European Directive 2002 95 EC Compliance is based on declaration that materials banned in the RoHS Directive are either 1 bel...

Отзывы: