Reversing the battery polarity may damage the product and the battery.
Dispose of used batteries according to local regulations and the battery manufacturer's
instructions.
Follow the battery manufacturer's instructions when installing the external UPS battery (not
provided).
Replacing the RTC backup battery
Strato Pi UPS has a hardware real time clock with a dedicated long-life non-rechargeable
back-up battery.
Strato Pi UPS is shipped with a
CR1025
Lithium / Manganese Dioxide (Li/MnO2) battery
installed.
The battery is only used to power the RTC chip when the main or UPS battery power is not
available (when the Raspberry Pi is off). Depending on operating conditions it should last
up to two years if the Strato Pi board is not powered, more if the Strato Pi UPS receives
external power.
Improper handling of lithium batteries can result in an explosion of the batteries and/or
release of harmful substances.
Worn-out or defective batteries can compromise the function of this product.
KEEP OUT OF REACH OF CHILDREN
. Swallowing may lead to serious injury or death in
as little as 2 hours due to chemical burns and potential perforation of the esophagus.
Immediately see doctor.
Replace the RTC lithium battery before it is completely discharged. Replace the battery
every 5 years even if the battery is still working properly. The lithium battery must be
replaced only with an identical
CR1025
Lithium / Manganese Dioxide (Li/MnO2) battery.
Do not throw lithium batteries into fire, do not solder on the cell body, do not recharge, do
not open, do not short-circuit, do not reverse polarity, do not heat above 100°C and protect
from direct sunlight, moisture and condensation.
Dispose of used batteries according to local regulations and the battery manufacturer's
instructions.
The RTC backup battery holder is soldered to the bottom layer of the circuit board,
between the GPIO connectors. In the Strato Pi UPS server, the battery is not accessible
from the outside. You should first remove the case top body to gain access to the Strato Pi
UPS circuit board.
Before opening the Strato Pi UPS case, disconnect all power sources, any connection to
external devices, including USB cables, and disconnect the UPS external battery.
WARNING
NOTICE
11
Strato Pi UPS User Guide
Содержание SPBU30X
Страница 26: ...35C AMBIENT TEMPERATURE LOW CPU LOAD 35C AMBIENT TEMPERATURE HIGH CPU LOAD 25 Strato Pi UPS User Guide...
Страница 27: ...45C AMBIENT TEMPERATURE LOW CPU LOAD 45C AMBIENT TEMPERATURE HIGH CPU LOAD 26 Strato Pi UPS User Guide...
Страница 28: ...Block diagram STRATO PI UPS BLOCK DIAGRAM 27 Strato Pi UPS User Guide...
Страница 31: ...Dimensions DIMENSIONS mm 30 Strato Pi UPS User Guide...