SITE PREP TASKS
SELECTING THE SITE
Decide where to install the printer based on the following:
1. Space Requirements
2. Workstation Requirements
3. Environmental Requirements
4. Electrical Requirements
5. LAN Requirements
SPACE REQUIREMENTS
UNCRATED DIMENSIONS AND WEIGHTS
Make sure that the installation location can accommodate the printer’s weight and dimensions, plus required
clearances. The installation location must be a stable flat surface capable of holding 350 pounds (159 kg).
MINIMUM CLEARANCES
Sufficient rear and side clearances allow for proper air circulation, while sufficient front clearance allows enough
room for the oven door to be opened.
ENVIRONMENTAL REQUIREMENTS
•
The Dimension 1200es printer is for indoor use only.
•
Air quality conditions with excessive solid particulates (conductive or non-conductive) may
result in system damage.
•
Air quality conditions in which airborne oils are allowed to accumulate on or within the printer
can damage the plastic components.
•
Operating temperature shall be in the range of 59°F to 86°F (15°C to 30°C), with relative
humidity range of 30% to 70% non-condensing.
•
Storage temperature shall be in the range of -40°F to 129.2°F (-40°C to 54°C), with relative
humidity range of 10% to 85% non-condensing.
•
Altitude shall not exceed 6561.68 feet (2000 m).
•
Typical heat emission shall be 1080 Watts = 3686 BTU/hour, and maximum heat emission shall
be 1380 Watts = 4710 BTU/hour.
Height
45 inches (114.3 cm)
Width
29 inches (73.7 cm)
Depth
33 inches (83.8 cm)
Weight
326 pounds (148 kg)
Side Clearance
Minimum 6 inches (15.2 cm) on each side
Rear Clearance
Minimum 4.5 inches (11.4 cm)
Front Clearance
Minimum 17 inches (43.2 cm)