In case of problems, contact your local dealer if no our authorized maintenance man.
In order to guarantee that arc welding machine works high-efficiently and in safety, it must be
maintained regularly. Let customers understand the maintenance methods and means of arc
welding machine more , enable customers to carry on simple examination and safeguarding by
oneself, try one's best to reduce the fault rate and repair times of arc welding machine, so as to
lengthen service life of arc welding machine .Maintenance items in detail are in the following
table.
•
Warning: For safety while maintaining the machine, please shut off the supply power and wait
for 5 minutes, until capacity voltage already drop to safe voltage 36V.
Date
Maintenance items
Daily
examination
Observe that whether panel knob and switch in the front and atthe back of
arc welding machine are flexible and put correctly in place. Ifthe knob has not
been put correctly in place, please correct; If you can't correct or fix the knob ,
please replace immediately;
Ifthe switch is notflexible or it can't be put correctly in place, please replace
immediately; Please getin touch with maintenance service departmentifthere
are no accessories.
After turn-on power, watch/listen to that whether the arc welding machine
has shaking, whistle calling or peculiar smell. Ifthere is one ofthe above
problems, find outthe reason to get rid of; if you can'tfind outthe reason,
Please contact local this area agent or the branch company.
Observe that whether the display value of LED is intact. Ifthe display
number is notintact, please replace the damaged LED. Ifit still doesn’t work,
please maintain or replace the display PCB.
Observe that whether the min/max value on LED accords with the set value.
Ifthere is any difference and it has affected the normal welding craft, please
adjustit.
Check up that Whether fan is damaged and is normal to rotate or control. If
the fan is damaged, please change immediately. Ifthe fan does not rotate after
the arc welding machine is overheated , observe that whether there is something
blocked in the blade, ifitis blocked, please get rid of ; Ifthe fan does not rotate
after getting rid ofthe above problems, you can poke the blade by the rotation
direction offan. Ifthe fan rotates normally, the start capacity should be
replaced; If not, change the fan.
Observe that whether the fast connector is loose or overheated. ifthe arc
welding machine has the above problems, it should be fastened or changed.
9. MAINTENANCE & TROUBLESHOOTING
9.1 Maintenance
39
www.strata.co.nz
EZIMIG185C
Содержание EZIMIG185C
Страница 12: ...Figure 33 Figure 34 Figure 35 Figure 36 11 www strata co nz EZIMIG185C ...
Страница 43: ...9 3 Electrical schematic drawing 42 www strata co nz EZIMIG185C ...
Страница 45: ...44 www strata co nz EZIMIG185C ...
Страница 46: ...45 www strata co nz EZIMIG185C ...
Страница 47: ...46 www strata co nz EZIMIG185C ...