SPX LED WW LUMINAIRE QUICK START GUIDE
3
02.1704.0010
15 AUGUST 2018
A safety cable MUST always
be used when rigging
luminaires on bars, truss, etc.
A safety cable is
recommended for all hanging
installations and may be
required by national and
local codes. Loop or attach
safety cable to luminaire
safety cable anchor point as
shown and attach to
structure. You should always
consult and follow all local
and national codes and
regulations for mounting and
installation of luminaire.
OPERATING THE LUMINAIRE
To set DMX address:
Step 1. At default screen, press LEFT or RIGHT arrow button once.
Step 2. Press LEFT or RIGHT arrow buttons to scroll to DMX Address.
Step 3. Hit [OK] to change DMX address.
Step 4. Press [ESC] at any time to access Main Menu.
Use with Mains Dimming
In order for the SPX LED WW to dim between 0% and 100%, the connected dimmer must provide a
minimum voltage to ensure the fixture is powered and ready to dim. The minimum required voltage
level is shown in the tables below. When the dimmer output falls below the specified minimum, the
SPX LED WW powers off.
For optimal performance, the dimmer should be configured to always generate the minimum required
voltage level when the control signal from the console is at 0%. This can be achieved by adjusting the
dimmer output law (sometimes refereed to as “dimmer curve,” “preheat” or “bottom set” depending on
the manufacturer). Alternatively, it may be possible to produce the same effect by adjusting the output
curve of your console. Consult the manufacturer of your dimmer/console for the specific steps
required.
Note:
Strand
Lighting technicians cannot provide instructions for adjusting the output curve on
dimmers/consoles not manufactured by
Strand
Lighting.
It is possible to use a dimmer
or console that has not been
adjusted. However, you may
experience different
performance characteristics
and behaviors, including
delays when flashing to full.
Beam Shutter Operation
A safety cable MUST always be
used when rigging luminaires on bars, truss, etc. A safety cable is recommended for all hanging
installation and may be required by national and local codes.
Safety Cable
(sold separately)
Safety Cable
(not supplied)
Safety Cable
Anchor Point
SAFETY CABLE:
FOR
LUMINAIRE,
a safety cable is
recommended for all hanging
installations and may be
required by national and local
codes. Loop safety cable
through luminaire safety
cable anchor point.
FOR
LENS TUBE
, attach a safety
cable (sold separately) to lens
tube anchor point and to
yoke assembly.
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
0%
20%
40%
60%
80%
100%
Dimmer
%
Output %
Dimmer % to Output % on 115V
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
0%
20%
40%
60%
80%
100%
Dimmer
%
Output %
Dimmer % to Output % on 230V