Strand Lighting SPX LED WW Скачать руководство пользователя страница 3

SPX LED WW LUMINAIRE QUICK START GUIDE

3

02.1704.0010

15 AUGUST 2018

A safety cable MUST always 
be used when rigging 
luminaires on bars, truss, etc. 
A safety cable is 
recommended for all hanging 
installations and may be 
required by national and 
local codes. Loop or attach 
safety cable to luminaire 
safety cable anchor point as 
shown and attach to 
structure. You should always 
consult and follow all local 
and national codes and 
regulations for mounting and 
installation of luminaire.

OPERATING THE LUMINAIRE

To set DMX address:

Step 1. At default screen, press LEFT or RIGHT arrow button once. 

Step 2. Press LEFT or RIGHT arrow buttons to scroll to DMX Address.

Step 3. Hit [OK] to change DMX address.

Step 4. Press [ESC] at any time to access Main Menu.

Use with Mains Dimming

In order for the SPX LED WW to dim between 0% and 100%, the connected dimmer must provide a 
minimum voltage to ensure the fixture is powered and ready to dim. The minimum required voltage 
level is shown in the tables below. When the dimmer output falls below the specified minimum, the 
SPX LED WW powers off.

For optimal performance, the dimmer should be configured to always generate the minimum required 
voltage level when the control signal from the console is at 0%. This can be achieved by adjusting the 
dimmer output law (sometimes refereed to as “dimmer curve,” “preheat” or “bottom set” depending on 
the manufacturer). Alternatively, it may be possible to produce the same effect by adjusting the output 
curve of your console. Consult the manufacturer of your dimmer/console for the specific steps 
required.

Note:  

Strand

 Lighting technicians cannot provide instructions for adjusting the output curve on 

dimmers/consoles not manufactured by 

Strand

 Lighting.

It is possible to use a dimmer 
or console that has not been 
adjusted. However, you may 
experience different 
performance characteristics 
and behaviors, including 
delays when flashing to full.

Beam Shutter Operation

A safety cable MUST always be 

used when rigging luminaires on bars, truss, etc. A safety cable is recommended for all hanging 
installation and may be required by national and local codes.

Safety Cable

(sold separately)

Safety Cable

(not supplied)

Safety Cable

Anchor Point

SAFETY CABLE: 

FOR 

LUMINAIRE, 

a safety cable is 

recommended for all hanging 
installations and may be 
required by national and local 
codes. Loop safety cable 
through luminaire safety 
cable anchor point. 

FOR 

LENS TUBE

, attach a safety 

cable (sold separately) to lens 
tube anchor point and to 
yoke assembly.

0%

10%

20%

30%

40%

50%

60%

70%

80%

90%

100%

0%

20%

40%

60%

80%

100%

Dimmer

 %

Output %

Dimmer % to Output % on 115V

0%

10%

20%

30%

40%

50%

60%

70%

80%

90%

100%

0%

20%

40%

60%

80%

100%

Dimmer

 %

Output %

Dimmer % to Output % on 230V