Filling pressure list gas springs 

                                                               

Näherungswerte, Abweichungen möglich / Approximate values, tolerances possible / Valeurs approchées, tolérances possibles

[bar]       [daN]

Nenndruck

     

 Nominal

 pressure

 / Pression

 nominale

Nennkraft

     

 Nominal

 force

 / Force

 nominale

Gasdruckfedern

 

                                     Fülldruck in bar / Filling pressure in bar / Pression de remplissage en bar 

      F max.    P max. 

Gas springs

 

              

 

  

 

 

 

 

 

 

 

 

  

Ressorts à gaz

 

30  40  50 

60  70  80  90  100  110  120  130  140  150  160  170     

[daN] 

[bar]

   

Zylinderkraft in daN bei Fülldruck in bar

 

 

 

 

            Cylinder force in daN at filling pressure in bar

 

 

                     Force du cylindre en daN à pression de remplissage en bar

  SN2820-C-7500 

150 

7500  50,27  1508  2011  2514  3016  3519  4022  4524  5027  5530  6032  6535  7038  7541 

 

 

7541 

150

  SN2820-P-9500 

150 

9500  63,62  1909  2545  3181  3817  4453  5090  5726  6362  6998  7634  8271  8907  9543 

 

 

9543 

150

  SN2820-A-10000

  141  10000  70,88  2126  2835  3544  4253  4962  5670  6379  7088  7797  8506  9214  9923  10632 

 

  10632 

150

  SN2820-C-10000 

141  10000  70,88  2126  2835  3544  4253  4962  5670  6379  7088  7797  8506  9214  9923  10632 

 

  10632 

150

  SN2825-750

 

150 

750  4,91  147  196  246  295  344  393  442  491  540  589  638  687  736 

 

 

737 

150

  SN2825-1250

 

175 

1250  7,07  212  283  354  424  495  566  636  707  778  848  919  990  1061  1131  1202 

1237 

175

  SN2825-1500

 

148 

1500  10,18  305  407  509  611  713  814  916  1018  1120  1222  1323  1425  1527 

 

 

1527 

150

  SN2825-1800

 

175 

1800  10,18  305  407  509  611  713  814  916  1018  1120  1222  1323  1425  1527  1629  1731 

1782 

175

  SN2825-3000

 

150 

3000  19,63  589  785  982  1178  1374  1570  1767  1963  2159  2356  2552  2748  2945 

 

 

2945 

150

  SN2825-5000

 

150 

5000  33,18  995  1327  1659  1991  2323  2654  2986  3318  3650  3982  4313  4645  4977 

 

 

4977 

150

  SN2830-350

 

138 

350  2,54  76  102  127  152  178  203  229  254  279  305  330  356  381 

 

 

381 

150

  SN2830-500

 

132 

500  3,80  114  152  190  228  266  304  342  380  418  456  494  532  570 

 

 

570 

150

  SN2830-1000

 

142 

1000  7,06  212  282  353  424  494  565  635  706  777  847  918  988  1059 

 

 

1059 

150

  SN2830-1500

 

148 

1500  10,17  305  407  509  610  712  814  915  1017  1119  1220  1322  1424  1526 

 

 

1526 

150

  SN2900-420

 

133 

420  3,14  94  126  157  188  220  251  283  314  345  377  408  440  471 

 

 

471 

150

  SN2900-750

 

150 

750  4,90  147  196  245  294  343  392  441  490  539  588  637  686  735 

 

 

735 

150

  SN2900-7000

 

139 

7000  50,27  1508  2011  2514  3016  3519  4022  4524  5027  5530  6032  6535  7038  7541 

 

 

7541 

150

  SN2900-7500

 

150 

7500  50,26  1508  2010  2513  3016  3518  4021  4523  5026  5529  6031  6534  7036  7539 

 

 

7539 

150

  SN2900-11800

 

150  11800  78,54  2356  3142  3927  4712  5498  6283  7069  7854  8639  9425  10210  10996  11781 

 

  11781 

150

  SN2900-18300

 

150  18300    122,72  3682  4909  6136  7363  8590  9818  11045  12272  13499  14726  15954  17181  18408 

 

  18408 

150

  SN2901-7500

 

150 

7500  50,26  1508  2010  2513  3016  3518  4021  4523  5026  5529  6031  6534  7036  7539 

 

 

7539 

150

  SN2901-11800

 

150  11800  78,54  2356  3142  3927  4712  5498  6283  7069  7854  8639  9425  10210  10996  11781 

 

  11781 

150

  SN2901-18300

 

150  18300    122,72  3682  4909  6136  7363  8590  9818  11045  12272  13499  14726  15954  17181  18408 

 

  18408 

150

  SN2902-1000 

150 

1000  7,07  212  283  354  424  495  566  636  707  778  848  919  990  1061 

 

 

1061 

150

  SN2902-1800

 

142 

1800  12,57  377  503  629  754  880  1006  1131  1257  1383  1508  1634  1760  1886 

 

 

1886 

150

  SN2902-2000 

155 

2000  12,57  377  503  629  754  880  1006  1131  1257  1383  1508  1634  1760  1886 

 

 

1948 

155

  SN2902-3000

 

150 

3000  19,63  589  785  982  1178  1374  1570  1767  1963  2159  2356  2552  2748  2945 

 

 

2945 

150

  SN2902-4700

 

150 

4700  31,17  935  1247  1559  1870  2182  2494  2805  3117  3429  3740  4052  4364  4676 

 

 

4676 

150

  SN2910-M16

 

175 

50  0,28 

11 

14 

17 

20 

22 

25 

28 

31 

34 

36 

39 

42  45 

48 

49 

175

  SN2910-M24

 

175 

140  0,78  23 

31 

39 

47 

55 

62 

70 

78 

86 

94  101  109  117  125  133 

137 

175

  SN2910-M28

 

175 

200  1,13  34 

45 

57 

68 

79 

90  102  113  124  136  147  158  170  181  192 

198 

175

  SN2910-M38x1.5

  142 

250  1,77  53 

71 

89  106  124  142  159  177  195  212  230  248  266 

 

 

266 

150

  SN2910-M45

 

150 

750  4,90  147  196  245  294  343  392  441  490  539  588  637  686  735 

 

 

735 

150

  SN2910-M50

 

142 

1000  7,06  212  282  353  424  494  565  635  706  777  847  918  988  1059 

 

 

1059 

150

Содержание PowerMax SN5650-PMU-0330

Страница 1: ...CAM UNIT SN5650 PMU 0330 SN5650 PMU 1200 OPERATING INSTRUCTIONS PowerMax...

Страница 2: ...1 Mounting of the Lock Out System 5651 PMU LOS 0330 18 10 1 2 Mounting of the Lock Out System 5651 PMU LOS 0460 5651 PMU LOS 1000 20 10 2 Lock Out System 5654 LOS 22 10 2 1 Information of the Lock Ou...

Страница 3: ...ed for all persons which are working with these cam units and which are responsible for the secure operating For reasons of the operating safety a copy of these operating instructions has to be left a...

Страница 4: ...nitrogen gas spring is used incorrectly or not for the intended application menace Dangers for the health Dangers for the STRACK nitrogen gas springs and other property holdings of the operator Danger...

Страница 5: ...transport company which has delivered the consignment Please compare the content of the consignment with the delivery note respectively the enclosed list of items see appendix Please also ascertain t...

Страница 6: ...r number and filling pressure different at the diverse cam types determine the reset force which is available Please consider that all PowerMax cam units are the successful result of a long developmen...

Страница 7: ...plates belong to these All cams can also be produced for the machining of high strength sheets contrary to the angles in five steps described in the catalogue in all intermediate angles according to...

Страница 8: ...reviously to choose a cam size which corresponds to the force To be able to guarantee an equal running life the load forces reduce according to the position on the working face You will find detailed...

Страница 9: ...ave to take care that punching wastes don t fall in or on the cam guidance Cam slide and guidances can seize Parts falling down can damage the guidances hereby possibly the running life of the cam red...

Страница 10: ...rain for them drainage borings cutouts and so on so that the fluids are directed away from the gas springs Thereby seal damages are avoided Tip Control the nitrogen pressure of the gas springs in regu...

Страница 11: ...ainers and slides can simplified be mounted together by means of the safety ring bolt SN1594 because of the fact that the different positions of the handling screwing thread facilitates the mounting o...

Страница 12: ...name and the serial number of the cam are lasered Name of the cam 6 digit serial number For additional information for customers The serial number refers to all cams of an order and is different conce...

Страница 13: ...ssible The high precision plate can be dismounted easily to be able to carry out further machining The mounting plate is not screwed with the cam slide to keep the complete working surface free of scr...

Страница 14: ...mps in direction OPEN 1 Then the clamps can be removed 2 picture 4 Step 3 Screw the safety ring bolts SN1594 in the plate to be able to lift it with a crane First lift the mounting plate out of the ce...

Страница 15: ...2018 I Operating instructions PowerMax cam unit PMU PowerMax PowerMax cam unit SN5650 PMU 0330 SN5650 PMU 1200 9 1 Mounting of the mounting plate at cam widths 0330 1200 only Premium The mounting is e...

Страница 16: ...instructions PowerMax cam unit PMU PowerMax PowerMax cam unit SN5650 PMU 0330 SN5650 PMU 1200 10 The Lock Out Systems 10 1 Lock Out System SN5651 LOS This lock out system can be used at mounted and di...

Страница 17: ...U 0400 0 SN5651 LOS SPS M16x120 2 SN5651 LOS DS 50x35 1 SN5651 PMU LOS 0460 SN5651 PMU 0460 SN5651 PMU LOS SPB 0460 1 SN5651 LOS SPS M16x160 2 SN5651 LOS DS 50x35 2 SN5651 PMU LOS 0580 1000 SN5651 PMU...

Страница 18: ...330 To fasten the cam for the insertion of borings the fixation of the cam slide by means of a lock out system is necessary For this purpose please act as following 1 Remove the gas spring by removing...

Страница 19: ...SN5650 PMU 1200 picture 3 picture 4 3 Now push the cam slide in the front position step 1 Turn the screws SN5651 LOS SPS M8 x 90 in the slide top step 2 Tighten the screws cautiously to fasten the ca...

Страница 20: ...650 PMU 1200 To fasten the cam for the insertion of borings the fixation of the cam slide by means of a lock out system is necessary For this purpose please act as following picture 1 picture 2 pictur...

Страница 21: ...Max PowerMax cam unit SN5650 PMU 0330 SN5650 PMU 1200 4 Now push the cam slide in the front position step 1 You can remove the slide stop step 2 5 Now screw the Lock Out System SN5651 PMU LOS at the p...

Страница 22: ...S 0330 10 10 SN3500 M12 45 1 SN3500 M12 60 1 SN5651 LOS DS 50x35 1 SN5654 PMU LOS 0330 15 15 SN3500 M12 45 1 SN3500 M12 65 1 SN5651 LOS DS 50x35 1 SN5654 PMU LOS 0330 20 20 SN3500 M12 50 1 SN3500 M12...

Страница 23: ...SN3500 M12 60 2 SN5651 LOS DS 45x35 2 PMU 0700 SN5654 PMU LOS 0700 00 00 SN3500 M12 50 1 SN3500 M12 40 2 SN5651 LOS DS 45x35 2 SN5654 PMU LOS 0700 05 05 SN3500 M12 50 1 SN3500 M12 40 2 SN5651 LOS DS 4...

Страница 24: ...the cam body is screwed with the cam reception The special thing is that the clamping screws act under an angle on the corresponding bearing face That means the cam body is once pulled by the divided...

Страница 25: ...to be able to turn the plug in Afterwards the plug has to be secured with the safety bolt and the washer 1 Remove the gas spring by removing at first the securing screw step 1 after wards remove the...

Страница 26: ...ed SN5652 PMU tye 1 Concerning the cam widths 580 and 700 mm 2 gas springs SN5652 PMU type 2 can be mounted and for the widths 850 and 1000 mm the stripper forces can be increased by 3 gas springs SN5...

Страница 27: ...650 PMU 0330 SN5650 PMU 1200 3 To remove the filling valve turn the discharging lug and turn the filling valve to the left till it loosens 2 To let the gas escape you turn the discharging lug SN2955 i...

Страница 28: ...with the connector G1 8 in the gas spring Continue with step 3 For the gas springs with the connecting thread M6 A M8 2a Turn the adapter M6 A M8 on the connecting thread G1 8 2b Turn the charging equ...

Страница 29: ...lve slowly in till the pressure escapes or till the desired pressure is indicated at the manometer Finally turn the adjusting screw of the discharge valve immediately back in the initial position You...

Страница 30: ...ring of the system pressure of the gas springs in the cam units Accident Prevention Regulation Please check the system pressure of the gas spring before restarting the tool If you have to increase the...

Страница 31: ...B Pull the adjusting wedge back and put the driver on the prism of the cam slide After the installation of the driver on the cam slide push the active returns on the inserts of the driver and fix the...

Страница 32: ...de frottement 0 05 0 15 PV Wert PV value Valeur PV 2950 daN cm2 x m min Fl chenpressung max Surface pressure max Pression superficielle maximale 76 N mm2 Arbeitstemperatur Operating temperature Temp...

Страница 33: ...ld exchange the low maintenance slide rails when they are damaged The hardened steel rails are adapted to the respective guide clearance of the cam and should not be exchanged in the normal case The l...

Страница 34: ...ons PowerMax cam unit PMU PowerMax PowerMax cam unit SN5650 PMU 0330 SN5650 PMU 1200 Bronze with solid lubricant SNS Sinter metal Application test in the cam of a cutting tool Test tool Counter bearin...

Страница 35: ...rMax cam unit PMU PowerMax PowerMax cam unit SN5650 PMU 0330 SN5650 PMU 1200 15 Appendix 15 1 Internet and CAD The company STRACK NORMA has created an online presence for the PowerMax cam elements whi...

Страница 36: ...rial fatigue and therefore also eliminating possible leakage points All STRACK gas springs are supplied with a quality certificate COMPONENT CHARACTERISTICS Body Developed in one piece up to strokes o...

Страница 37: ...s convenient to design with an optimal safety level It is therefore recommended to foresee a 10 stroke reserve picture 1 Working temperature Maximum working temperature is 80 C Higher temperatures can...

Страница 38: ...e will help you chose the most adequate product depending on the type of work you wish to carry out Garantee and duration The guarantee that STRACK offers in gas springs is for one year as from the da...

Страница 39: ...spring onto the tool in such a way it makes a free stem ejection possible The installation of a compressed gas spring is dangerous due to serious safety risks The gas spring is to work completely per...

Страница 40: ...643 724 804 884 965 1045 1126 1206 1206 150 SN2807 2100 150 2100 13 85 416 554 693 831 970 1108 1247 1385 1524 1662 1801 1939 2078 2078 150 SN2807 3000 150 3000 19 63 589 785 982 1178 1374 1570 1767...

Страница 41: ...356 381 394 155 SN2809 600 155 600 3 80 114 152 190 228 266 304 342 380 418 456 494 532 570 589 155 SN2809 750 150 750 4 90 147 196 245 294 343 392 441 490 539 588 637 686 735 735 150 SN2809 1000 142...

Страница 42: ...8 266 304 342 380 418 456 494 532 570 570 150 SN2830 1000 142 1000 7 06 212 282 353 424 494 565 635 706 777 847 918 988 1059 1059 150 SN2830 1500 148 1500 10 17 305 407 509 610 712 814 915 1017 1119 1...

Страница 43: ...sberger Str 11 D 58511 L denscheid Tel 49 2351 8701 0 www strack de 08 2018 I Operating instructions PowerMax cam unit PMU PowerMax PowerMax cam unit SN5650 PMU 0330 SN5650 PMU 1200 PowerMax cam unit...

Страница 44: ...Max cam unit SN5650 PMU 0330 SN5650 PMU 1200 16 Exploded view and item list On the following pages you will find an exploded view and an item list exemplary like it can be down loaded on the internet...

Страница 45: ...mbH Co KG K nigsberger Str 11 D 58511 L denscheid Tel 49 2351 8701 0 www strack de 08 2018 I Operating instructions PowerMax cam unit PMU PowerMax PowerMax cam unit SN5650 PMU 0330 SN5650 PMU 1200 Par...

Страница 46: ...08 2018 STRACK NORMA GmbH Co KG K nigsberger Str 11 D 58511 L denscheid Postfach 16 29 D 58466 L denscheid Tel 49 2351 8701 0 Fax 49 2351 8701 100 Mail info strack de Web www strack de...

Отзывы: