Stove Guard Guardian 2010 Скачать руководство пользователя страница 7

Page 7 of 7

Password is: 1-2-3-4.
Automatically goes to AUTO from SG-OFF mode.
Default preset time in Auto mode is 1 minute.
Delay model.
SG-OFF LED shows SG-OFF mode.
Repeating setting for buzzer and output connector in Auto and Timer mode.

SENSING LEVEL ADJUSTMENT (Height Adjustment)

The sensing range of the EMU (

Electronic Monitoring Unit

) is over 4 meters (around 12 feet) at a radius of 110 degrees.

Each time the motion sensor is activated, the green INDICATOR LED flashes (

#8 on EMU Diagram

).



STOVE GUARD

features an adjustable sensing height level to prevent the activation of the stove by small

children or pets that might be detected by the motion sensor (PIR).



There is a screw located underneath the EMU, which allows you to adjust the viewing height range of the PIR.
Normally this does not need to be adjusted.

Note

: This adjustment should only be done in the following situations:

1.

It is determined that the PIR is detecting movements other than those of the intended

STOVE GUARD

user (

such

as small children, pets, etc.

) which will pass within the lower portion of it’s detection field.



To

RAISE the detection field

when the EMU cannot be located higher, slowly turn the screw to the

LEFT

.

2.

STOVE GUARD

is not detecting the movements of the user because its location is set very high up; the user is

very short, or seated in a wheelchair.



To

LOWER the detection field

for these situations, slowly turn the screw to the

RIGHT

.

TROUBLESHOOTING

Why is there a very slight “…humming sound…” coming from the Stove Guard’s power box?

This humming sound is normal; the sound is emitted from the energized coils in the power relays. These relay coils must
be energized to allow the operation of the safety feature called “…Fail Safe…”. This important added safety feature makes
the Stove Guard tamper proof, this means that if any wires are purposely disconnected to try to disarm Stove Guard the
kitchen stove will not operate.

If this slight humming sound is annoying to you, try to lay the Power Box on the floor behind the stove instead of
mounting it to the wall… When attached firmly to the wall or metal surface the sound may be amplified.

The EMU’s LED’s do not light up:



Check the stove fuse or circuit breaker to ensure power is reaching the stove.



Check that all the connections to the

STOVE GUARD

Power Box and EMU are properly connected and press

the AUTO button.



Check the fuse in the

STOVE GUARD

Power Box

(#2 on POWER BOX diagram

).

The green INDICATOR LED flashes without any reason:

Avoid placing the EMU within the proximity of the following sources of interference that might accidentally trigger the PIR
(

Motion Detector

):



Reflective Surfaces: direct air flow from vents, fans and windows.



Sources of steam or cooking oil vapor.



Infrared light sources: TV or other IR Remote Controls



Objects causing temperature changes: such as heaters, refrigerators, toasters and ovens.



Do not place objects that a pet can climb onto (

e.g. a cat on furniture

) within 10 feet of the EMU, or furniture

higher than 3 ft.



In addition, do not aim the EMU at a stairway a pet may have access to.

Содержание Guardian 2010

Страница 1: ...ation of STOVE GUARD does not require the use of a licensed Electrician Read this manual first to familiarize yourself before installing hire a professional if you are uncomfortable with doing the ins...

Страница 2: ...t during installation 4 Cord to EMU 5 Mounting Brackets 6 220 240V Stove Receptacle 1 4 2 3 1 5 4 Side View Front View 6 1 SG OFF button 2 AUTO MODE button to activate Motion Detector PIR 3 STOVE OFF...

Страница 3: ...the other operating position 3 on the Power Box Diagram Test the clock and light operation again Stove Guard should shut off the stove but not affect the clock or stove lights 9 Make sure nothing is...

Страница 4: ...me The green AUTO LED lights Green movement indicator lights every time when movement is detected and resets clock to the preset time Display will show number of minutes left before Stove Guard turn o...

Страница 5: ...re type situations Administrators can set the device to the User s particular needs and then password lock it If buttons are locked only the unlock function is enabled To lock unlock Stove Guard s but...

Страница 6: ...l choose one Standard Add 0 Delay Add 1 Password Add 2 Possible left digit settings 0 8 Right digit meaning Red SG OFF LED meaning choose one Lights when Stove Guard is in the SG OFF mode Add 0 Lights...

Страница 7: ...ESHOOTING Why is there a very slight humming sound coming from the Stove Guard s power box This humming sound is normal the sound is emitted from the energized coils in the power relays These relay co...

Страница 8: ...us at 1 888 607 8683 1 888 60 STOVE or email us at techsupport stoveguardintl com to obtain a return merchandise authorization number RMA 2 Return the defective unit postage paid to the address shown...

Отзывы: