3.  Make sure sump is free of string, cloth, nails, 

gravel, etc. before installing pump.

4.  Pump is to be connected to a properly 

grounded, grounding type receptacle only.

5.  Do not remove ground pin from electrical plug.

6.  Do not use an extension cord.

7.  Connect to separate electrical circuit taken 

directly from main switch.

8.  Use steel or plastic pipe for all connecting lines 

between pump and sewer outlet.

note: Some city regulations do not allow 

installing a pump with plastic pipe. Check local 

regulations.

9.  In applications where the pump may sit idle 

for months at a time, it is recommended that 

the pump(s) be cycled every month to ensure 

the pumping system is working properly when 

needed.

10. A check valve should be installed in discharge 

pipe at least 12" above the discharge outlet of 

the pump.

11.  For greater protection, an audible alarm should 

be used with all pump installations to indicate a 

high water condition exists.

,RQ_6WRUP3UR

SP50

 

OS50

Submersible Effluent Pump

OPERATION MANUAL

Dated: 08/04/10

Supersedes: None

Document No.: 23833A669

Page 

2

 of 4

Содержание SP50

Страница 1: ...use sparkable electrical devices or flames in a septic gaseous or possible septic sump Pump Warning To reduce risk of electrical shock 1 Risk of Electrical Shock This pump has not been in ves ti gat ed for use in swimming pool marine areas 2 Risk of Electrical Shock Connect only to a properly ground ed receptacle Septic tank is to be vented in ac cor dance with local plumbing codes Do not smoke or...

Страница 2: ...s do not allow installing a pump with plastic pipe Check local regulations 9 In applications where the pump may sit idle for months at a time it is recommended that the pump s be cycled every month to ensure the pumping system is working properly when needed 10 A check valve should be installed in discharge pipe at least 12 above the discharge outlet of the pump 11 For greater protection an audibl...

Страница 3: ...Notes TOTAL DYNAMIC HEAD FEET 0 16 8 24 32 0 10 20 30 40 50 60 CAPACITY U S G P M 1 2 HP RQ_6WRUP3UR SP50 OS50 Submersible Effluent Pump OPERATION MANUAL Dated 08 04 10 Supersedes None Document No 23833A669 Page 3 of 4 ...

Страница 4: ...soon as a problem is discovered No request for service will be accepted if received after the Warranty Period has expired This warranty is non transferable STORMPRO SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL INCIDENTAL OR CONTINGENT DAMAGES WHATSOEVER THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF...

Отзывы: