WARNING!

Electric shock can cause DEATH or SEVERE PERSONAL INJURY.

Always observe the following precautions when working:

1.

Never touch exposed conductors of electricity with fingers, hands or
any other body part.

2.

Use caution when working near voltages above  30 VAC  rms,  42 VAC
peak, or 60 VDC.

  Voltages this high present a risk of electric shock.

3.

This device is only intended to test live circuits.  Do not rely on this
device alone to detect if a circuit is live or not.

  A faulty circuit, a voltage

out of this tester’s range, or an unseen failure in the device can all result in an
incorrect negative reading.

4.

Hold the Tester only on the handle section.  Keep fingers well away from
the metal screwdriver section.

5.

Whenever possible, have an assistant nearby.

6.

Never force the blade of the tester into any opening.

  Forcing this tool may

damage the tool and/or the electrical component being tested, potentially
creating a risk of fire or electric shock.

7.

Do not rely on this device to detect voltages out of its range (110-250V).

Testing other voltages may produce unpredictable, or hazardous, results.

Operation

1.

Make sure that the tester is clean, dr y, and in good condition.  Hold the Tester
with one hand on the handle portion only.

2.

Place the Blade of the Tester on the conductor to be tested.

3.

Place one finger on the metal button on the end of the Tester.

4.

Look at the window.  If the light illuminates, the tester has detected voltage.

blade

window

metal

button

(hidden)

handle

110 - 250V Screwdriver Light Tester (9)

Содержание 92970

Страница 1: ...ight com Copyright 2005 by Harbor FreightTools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools For technical questions and replacement parts please call 1 800 444 3353 92970 WARNING Electric shock can cause DEATH or SEVERE PERSONAL INJURY Never touch exposed conductors o...

Страница 2: ...azardous situation which if not avoided could result in death or serious personal injury CAUTION indicates a potentially hazardous situation which if not avoided may result in a minor moderate personal injury or damage to this tool or the unit being tested by it Multimeter Specifications M E T I N O I T P I R C S E D M E T I N O I T P I R C S E D s e g n a R e g a t l o V C A V 0 0 5 0 5 2 0 5 0 1...

Страница 3: ...ally nonconductive clothes and nonskid rubber soled footwear are recommended when working Wear restrictive hair covering to contain long hair 9 Use eye protection Always wear ANSI approved impact safety goggles 10 Do not overreach Keep proper footing and balance at all times Do not reach over or across electrical cables or frames 11 Maintain tools with care Ensure multimeter has a fresh battery Ke...

Страница 4: ... Do not test voltage on circuits higher than 500 volts Do not test current on DC circuits higher than 5 amps or on AC circuits at all 21 The included Anti static Wrist Strap 5 is intended solely to help mini mize static shock damage to sensitive electronics THEWRIST STRAP IS NOT DESIGNED TO PROTECT THE USER FROM ELECTRIC SHOCK 22 Never apply flame to the heat shrink tubing The heat shrink tubing i...

Страница 5: ... e s a C 1 0 1 s l a n i m r e T d e t a l u s n I 9 3 2 e p a T l a c i r t c e l E 0 3 1 1 s l a n i m r e T d e t a l u s n i n o N 0 5 3 r e v i r d w e r c S s s o r C 1 2 1 s r o t c e n n o C e r i W 0 5 4 r e v i r d w e r c S d e t t o l S 1 3 1 s r e d n i B k c o L 5 2 5 p a r t S t s i r W c i t a t s i t n A 1 4 1 y r e t t a B w r e t e m i t l u M 1 6 l o o T g n i p m i r C 1 5 1 s...

Страница 6: ...is noted on the scale this function is not available for this item The Accuracy Mirror The Accuracy Mirror is used to insure that the meter s pointer is being read straight ensuring accuracy Simply make sure that the meter is angled so that when reading it the reflection of the pointer is hidden under the pointer Jack BLACK lead Jack RED lead DC Current Selection Area mA 8 AC Volt Selection Area 8...

Страница 7: ... then the probes are con nected incorrectly Reverse the probes locations If the voltage is less than 250 volts set the Range Selector Switch to the next lower range until the meter pointer is mid range on the scale 5 When testing is complete switch the meter to OFF remove the Test Leads and store the leads and meter in the provided case e l a c S p m A t l o V e h t d a e R o t w o H e g n a R p m...

Страница 8: ... the 5 DCmA range and reconnect power 4 When testing is complete first disconnect power to the circuit switch the meter to OFF remove the Test Leads reconnect the circuit s ground side and store the leads and meter in the provided case Resistance Ohm Measurements Circuit resistance is measured at meter reading times 1 000 Note Testing resistance should ONLY be done with the power to the circuit di...

Страница 9: ...lace it on the small meter Zero Ad just screw right below the center of the dial See Control and Scale Layout on page 6 c Turn screw slightly until the pointer points directly at the zero Amperage Voltage Scale 7 Battery Replacement If the Ohms cannot be adjusted to indicate zero the battery requires replacement a Remove the Test Leads 15 from the multimeter and switch the multimeter to the OFF po...

Страница 10: ...old the Tester only on the handle section Keep fingers well away from the metal screwdriver section 5 Whenever possible have an assistant nearby 6 Never force the blade of the tester into any opening Forcing this tool may damage the tool and or the electrical component being tested potentially creating a risk of fire or electric shock 7 Do not rely on this device to detect voltages out of its rang...

Отзывы: