Ultra320 DE200 User's Guide - Rev. A01
StorCase Technology, Inc.
Installation
11
NOTE:
Option Pins 13-16 (Table 2) are used to remotely access the disk drive's motor
control options. Refer to the documentation provided by the drive manufacturer
for further information.
5.
Adjust the front of the receiving frame so the carrier slides freely in and out on the
receiving frame guides. The position of adjoining peripheral units may require ad-
justment.
Table 2: Option Pins 13-16 Drive Motor Control
Open
Open
Motor spins up on "Power On"
Open
Closed
Motor spins up only if SCSI
"Start" command is received
Closed
Open
Drive motor starts spinning up
approximately 12 seconds x the
SCSI ID number for each target
drive (12 second minimum)
Closed
Closed
Reserved
Closed = Jumper installed
Open = Jumper removed
DYST
RMST
Function