Interface Description
Communication Interface Definition
:
Pin
Name
Pin
NO.
Pin
Type
Interpret
GND
1,2
P
Power Ground
DIN
3,4
I
Data Input
DOUT
5,
O
Data Output
NC
6
None
VCC
7,8
P
Power Supply
Input
I: Input O: Output P: Power
Note A
: 1. Adopting the 8 Pin 2mm spacing socket.
2. Direction of the signal was defined with TFT-LCD Module;
“I” refers to the signal from the user’s system transmitted to the TFT-LCD Module.
3. Pins with the same definition are connected together in the module inside.
4. User can set the RS232 or 3.3 V TTL/CMOS level by soldering pad on the PCB.
Default is “OFF” (RS232 Level). If change to “ON”(TTL Level), only need to short
the soldering pad of J21, J22, and take out R60.
5. The RS485 and other interface can be customized which need to point out in the
order.
6.”Busy” signal doesn’t need to be considered as communication, Frame and
Command never be lost, (200MHz CPU,1M bit Command Buffer), “BUSY” signal
can be accessed to data input pin or left vacant.
Note B
: The selection of Baud rate for the serial interface
:
Baud rate
(
bps
)
1200
2400
4800
9600
19200
38600
57600
115200
Bode_Set
0x00
0x01
0x02
0x03
0x04
0x05
0x06
0x07
STVI101WT-01 Equipment Manual
-16-
Release 04/16