S
AT Command Reference
Release r02
www.stollmann.de
Page 10 of 33
&W
Store Active Configuration
AT syntax:
AT&W
The active configuration is stored in non-volatile memory.
A
Accept Incoming Call
AT syntax (normal mode):
ATA
AT syntax (MUX mode):
ATA <channel ID>
This command is supported for compatibility reasons only. A Bluetooth low energy
device has to answer every connection automatically. See also Register S0
description.
Examples:
ATA
Accepts connection in normal mode
ATA 0x01
Accepts connection in MUX mode at channel ID 0x01
BIOCAP
SSP I/O Capabilities
AT syntax:
AT+BIOCAP=<value>
This command sets the input and output capabilities of the device used for SSP.
Value
Description
0
Display only
1
Display Yes/No
2
Keyboard only
3
No input no output
4
Display and keyboard
BMITM
SSP Man in the middle protection
AT syntax:
AT+BMITM=<value>
This command controls the man in the middle (MITM) protection of the device during
SSP. It has to be set in context with
BIOCAP
command. In SSP there are scenarios
where MITM protection is not possible.