![Stoll Wood Grate Heater Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/stoll/wood-grate-heater/wood-grate-heater_installation-and-operating-instructions_1381778002.webp)
Assembly Instructions
Page 2
www.stollfireplaceinc.com
HARDWARE KIT:
1 ea. Wood Grate
1 ea. Vent Trim Cover with End Caps
1 set Rubber Grommet & Plug
1 ea. Blower Assembly
1 ea. 6’ Power Cord
5 ea. 1/4-20 Screws
1 ea. Heat Transfer Plate
1 ea. Variable Speed Switch Knob
1 ea. 1/4-20 Nut
1 ea. Air Outlet Vent
2 ea. Self Tapping Screws
PARTS INCLUDED FOR INSTALLATION:
PLEASE NOTE:
Your Stoll Grate Heater must be assembled and installed correctly.
Please read and follow all instructions carefully. Incorrect assembly or installation could result in a damaged
Grate Heater and/or a dangerous condition. Failure to heed these warnings could result in a fire and/or loss of
life and property. If you do not feel confident that you are equipped to complete the assembly and the installation
properly please contact your Stoll Dealer to arrange professional installation.
If you have questions:
Contact your Stoll Fireplace Dealer or Stoll Fireplace, Inc. before proceeding with installation.
Unpack the Grate Heater and identify all of the parts listed in the parts list above. Place the Wood Grate on a flat surface
with the manifolds facing toward you in preparation for assembly.
(Figure 1)
Locate the electrical power source nearest the fireplace. The Blower can be installed on the left or right side of the Grate
Heater. The Blower, Heat Transfer Plate, and the Power Cord should be installed on the side closest to the wall outlet.
Attach the Heat Transfer Plate
(“L” shaped part)
to the front Log Holder with 1/4-20 screw and nut.
(Figure 2)
Remove the cover from Blower Assembly. Install the Blower Assembly to the Grate Heater by tipping the Grate up and
sliding the manifold flange and the Heat Transfer Plate between the Blower Heat Shield and inner case.
NOTE:
The Heat Transfer Plate must be inside the Heat Shield and in contact with the Thermal Switch.
(Figure 3)
Fasten the Blower to the Grate Heater manifold using 2) 1/4-20 screws through the blower flange.
(Figure 3)
Attach the Warm Air Outlet Vent to the other manifold with 2) 1/4-20 screws.
(Figure 4)
Slide the Rubber Grommet onto the Power Cord. Insert the Rubber Grommet into the cutout in the Switch Case nearest
the power outlet. Install the Rubber Plug into the unused cutout in the opposite end of the switch case.
(Figure 5)
Connect the Power Cord to the Blower wiring. Connect Green to Green. Connect Power Cord White to Black from the
Blower. Connect Power Cord Black to Black from Speed Switch. See Wiring Diagram
(Figure 9)
on Page 4
.
Reinstall the Blower case cover with the fasteners removed in Step 4.
Assemble the Vent Trim Cover by sliding the two cover halves together and attach to the Grate Heater. The Vent Trim
Cover must be trimmed to size. If the Grate Heater is to be used with a fireplace enclosure, trim the Vent Trim Cover to
the same width as the fireplace enclosure. Alternately trim the Vent Trim Cover to the width of the fireplace opening. In-
stall the End Caps on the Vent Trim Cover with the cord cutout on the Blower end.
(Figure 6)
Reinstall the Vent Trim Cover onto the Grate Heater and fasten securely with 2 screws. Install the Switch Knob.
NOTE:
The Vent Trim Cover will not be used on Stoll Enclosures with laser cut vents in the frame.
Install the assembled Grate Heater into the fireplace. Level the grate using the leg leveling bolts.
(Figure 7)
Figure 2
Screw
Figure 3
Heat Shield
Thermal
Switch
Screws
Figure 4
Outlet
Vent
Figure 1
Manifolds
Wood Grate
Figure 5
Grommet
Plug
Figure 8
Assembled
Grate Heater
Figure 6
Vent Trim
Cover
Vent Trim
End Cap
Figure 7
Levelers