Stoelting A118 Скачать руководство пользователя страница 11

Owner’s Manual #513691 

A118/D118 Model Machines

Figure 3-1 Controls

SECTION 3

INITIAL SET-UP AND OPERATION

3.1  OPERATOR’S SAFETY PRECAUTIONS 

SAFE OPERATION IS NO ACCIDENT; observe these 

rules:
A. 

Know the machine. Read and understand the 

Operating Instructions.

B. 

Notice all warning labels on the machine.

C. 

Wear proper clothing. Avoid loose fitting garments, 

and remove watches, rings or jewelry that could 

cause a serious accident.

D. 

Maintain a clean work area. Avoid accidents by 

cleaning up the area and keeping it clean.

E. 

Stay alert at all times. Know which switch, push 

button or control you are about to use and what 

effect it is going to have.

F. 

Disconnect electrical cord for maintenance. Never 

attempt to repair or perform maintenance on the 

machine until the main electrical power has been 

disconnected.

G. 

Do not operate under unsafe operating conditions. 

Never operate the machine if unusual or excessive 

noise or vibration occurs.

3.2  OPERATING CONTROLS AND 

INDICATORS 

Before operating the machine, it is required that the op-

erator know the function of each operating control. Refer 

to Figure 3-1 for the location of the operating controls on 

the machine.

A. 

CLEAN-OFF-ON Switch

 

The CLEAN-OFF-ON switch is used to supply 

power to the control circuit. When the switch is in 

the OFF (middle) position, power is not supplied 

to the control board or refrigeration system. When 

the switch is in the ON position, the machine 

operates in the freezing mode. When the switch 

is in the CLEAN position, all refrigeration stops 

and the auger starts rotating. If left in the CLEAN 

position, defrost mode begins.

WARNING

High voltage will shock, burn or cause death. The 

OFF-ON switch must be placed in the OFF position 

prior to disassembling for cleaning or servicing. Do 

not operate machine with cabinet panels removed.

Diagnostic 

Light

Add Mix 

Light

Clean/Off/

On Switch

Содержание A118

Страница 1: ...Model A118 D118 OPERATORS MANUAL Manual No 513691 Rev 0...

Страница 2: ......

Страница 3: ...built prior to date of change DO NOT ATTEMPT to operate the machine until instructions and safety precautions in this manual are read completely and are thoroughly understood If problems develop or q...

Страница 4: ...ecific safety information the following safety defini tions are provided to assist the reader The purpose of safety symbols is to attract your at tention to possible dangers The safety symbols and the...

Страница 5: ...3 3 Removing Mix from Machine 6 3 4 Disassembly of Machine Parts 6 3 5 Cleaning Disassembled Parts 7 3 6 Cleaning the Machine 7 3 7 Assembling the Machine 7 3 8 Sanitizing 8 3 9 Freeze Down and Operat...

Страница 6: ......

Страница 7: ...They operate with almost any type of frozen beverage mix This manual is designed to help qualified service personnel and opera tors with the installation operation and maintenance of the Stoelting A11...

Страница 8: ...kg 240 lbs 108 8 kg Electrical 1 Phase 115 VAC 60Hz 1 Phase 208 240 VAC 60Hz 1 Phase 115 VAC 60Hz 1 Phase 208 240 VAC 60Hz running amps 10 2A 4 7A 13 6A 8 6A connection type NEMA5 20P power cord provi...

Страница 9: ...age on the freight bill If concealed damage and or shortage is found later advise the carrier within 10 days and request inspection The customer must place claim for damages and or shortages in shipme...

Страница 10: ...Owner s Manual 513691 4 A118 D118 Model Machines...

Страница 11: ...eunderunsafeoperatingconditions Neveroperatethemachineifunusualorexcessive noise or vibration occurs 3 2 OPERATING CONTROLS AND INDICATORS Before operating the machine it is required that the op erato...

Страница 12: ...local and state health codes Inspection for worn or broken parts should be made each time the machine is disassembled All worn or broken parts should be replaced to ensure safety to both the operator...

Страница 13: ...luster of the stainless steel A high grade of stainless steel has been used on the machine to ease cleanup To remove spilled or dried mix wash the exterior with 90 to 110 F 32 C to 43 C mild detergent...

Страница 14: ...the assembly into the spigot housing and rotate the assembly clockwise 90 to secure it L Installthespigothandleontothespigotassembly 1 Make sure the handle retaining pin is vertical Align the handle...

Страница 15: ...turn to freeze down product and return to normal operation 3 11 CONSISTENCY ADJUSTMENT The consistency adjustment screw is located behind the access plug on the right side panel Remove the plug to acc...

Страница 16: ...t be 3 8 I D minimum Make sure the machine is receiving an unrestricted supply of cold clean water 3 13 EXTENDED STORAGE Refer to the following steps for storage of the machine over any long period of...

Страница 17: ...efrost mode and flashes if an error occurs Refer to the chart below for details Indication On Two Blinks Conditions Defrost Mode Drive current is not sensed Self Correc tion N A The machine attempts t...

Страница 18: ...Section 3 4 Consistency setting too soft 4 Turn Consistency Adjustment knob clockwise 5 Auger is assembled incorrectly 5 Remove mix clean reassemble sanitize and freeze down 6 Refrigeration problem 6...

Страница 19: ...lades 1 324208 Decal Attention Refrigerant Leak Check 2 324509 Decal Cleaning Instructions 1 324566 Decal Wired According To 1 324584 Decal Adequate Ventilation 3 3 324686 Decal Danger Automatic Start...

Страница 20: ...2205308 2205002 625352 482019 2205672 Part Number Description Quantity 482019 Knob Front Door Black 4 624678 5 O Ring Rear Seal Black 5 Pack 1 625352 O Ring Front Door Black 1 666786 Seal Rear Auger B...

Страница 21: ...O Ring Valve Plug Inner 1 624654 O Ring Valve Plug Outer 1 624663 O Ring Retaining Cap 1 624715 O Ring Spigot Housing 1 694248 Spring Valve Plug Shaft 1 2205414 Retaining Cap Spigot Valve 1 2205417 H...

Страница 22: ...Owner s Manual 513691 16 A118 D118 Model Machines...

Страница 23: ...e obligations remedies are subject to the conditions that Buyer a signs and returns to Stoelting upon installation the Start Up and Training Checklist for the affected equipment b gives Stoelting prom...

Отзывы: