Страница 1: ...W FRSA110 Woodson Fryer Digital Auto Lift A guide on the use care and maintenance of your quality Woodson product Revision Date 15 05 2020 SPECIFICATION INSTALLATION AND OPERATION MANUAL READ ALL INSTRUCTIONS BEFORE USE ...

Страница 2: ...Page Intentionally Left Blank Page 1 Due to continuous product research and development the information contained herein is subject to change without notice www stoddart com au www stoddart co nz ...

Страница 3: ... 6 Handling Unpacking Positioning Disposal Specification Technical Specifications 7 W FRSA80 W FRSA110 Operation Initial Start up Operation 9 Control Panel Important Information Initial Start up Operation Automatic Operation Manual Over Temperature Cut Out After Hours Digital Timer Operation 10 Parameters Description Cleaning and Maintenance Cleaning 11 General Information Corrosion Protection Sur...

Страница 4: ...tion servicing or maintenance or lack of conformity with the instructions indicated in this documentation Disclaimer All units made by the manufacturer are delivered assembled where possible and ready to install Any installation removal servicing maintenance and access or removal of any parts panels or safety barriers that is not permitted does not comply in accordance to this documentation or not...

Страница 5: ... using any electrical unit safety precautions must always be observed Our units have been designed for high performance Therefore the unit must be used exclusively for the purpose for which it has been designed General Precautions Aggregate electrical ratings of the Unit are expressed in kilowatts in this manual Single Phase Units Supplied with an appropriately rated plug and lead fitted and be in...

Страница 6: ...ontained herein is subject to change without notice www stoddart com au www stoddart co nz Installation Rating Plate Located on rear of unit Over Temp Cut out Switch Located on rear of unit Control Panel CAUTION Surface is Hot Product Overview Drain Tap Fryer Basket Fryer Lid ...

Страница 7: ...aintenance Place the unit on a level stable work surface capable of supporting its weight Do not position the unit in wet areas near heat and or steam sources near flammable substances Allow an air gap between the unit and other objects or surfaces A minimum gap of 100mm from all sides is recommend for normal operational use if the unit is near any heat sensitive material allow additional space ex...

Страница 8: ... to change without notice www stoddart com au www stoddart co nz 272 429 701 530 Technical Specifications Specification W FRSA80 Specifications Model W FRSA80 Revision D Height 421mm Width 272mm Depth 530mm with basket 701mm Circuit Dedicated x 1 Power 240 V 3 6 kW 15A plug lead fitted Capacity 8Litre ...

Страница 9: ...s subject to change without notice www stoddart com au www stoddart co nz 272 456 651 666 767 Specification Specifications Model W FRSA110 Revision D Height 456mm Width 272mm Depth 666mm with basket 767mm Circuit Dedicated x 1 Power 240 V 4 8 kW 20A plug lead fitted Capacity 11 Litre W FRSA110 ...

Страница 10: ...olid oil under any circumstances Never use copper brass or plastic utensils in oil Keep unit covered when not in use DO NOT place lid over hot oil Check oil daily some foods that are fried degrade oil quicker than others change if necessary and ONLY when oil has cooled down The use of old cooking oil can reduce the flash point of the oil and make it more prone to surge boiling Surge boiling can al...

Страница 11: ...djust the parameter shown on the display The value can be modified with the UP and DOWN arrows Select Yes to turn alarm on select no to turn alarm off Press SET to store the value and exit to next parameter Countdown timer can use either Seconds or Minutes The time interval can be set from 1 999 Seconds Minutes When the timer countdown is not required the manual setting can be selected The alarm c...

Страница 12: ...emicals as this can cause corrosion After treatment wash with warm not hot soapy water and dry thoroughly Thoroughly wipe the surfaces dry after cleaning and do NOT let water pool on the unit Check crevices and folds for pooling When using ensure all liquids and moisture is cleaned up straight away Food liquids such as juices from vegetables and fruits should NOT be left on preparation surfaces Do...

Страница 13: ...ces using a cloth dampened not wet with clean warm water until all soil has been removed 6 Using a clean sanitised cloth thoroughly wipe the stainless steel and metal parts dry Do NOT let water pool on the unit Check crevices and folds 1 Wait until the oil and elements have cooled to a safe temperature 2 Drain the oil from the tank using the tap located on the front of the unit 3 Raise the heating...

Страница 14: ...oo Cold Temperature requires adjusting O Adjust Thermostat Oil too Hot Temperature requires adjusting O Adjust Thermostat Oil not Hot Element failure T Test replace the element if necessary Start button won t lower fryer basket Digital controller set to Manual Mode O Press SET to lower Raise fryer basket Enter settings and switch to Automatic Mode WARNING Technician tasks are only to be completed ...

Страница 15: ...Page 14 Due to continuous product research and development the information contained herein is subject to change without notice www stoddart com au www stoddart co nz ...

Страница 16: ...w Zealand Business Number 6837694 New Zealand Sales Tel 0800 79 1954 Email sales stoddart co nz Service Spare Parts Tel 0800 935 714 Email service stoddart co nz Email spares stoddart co nz www stoddart com au Australian Business Number 16009690251 Australia Sales Tel 1300 79 1954 Email sales stoddart com au Service Spare Parts Tel 1300 307 289 Email service stoddart com au Email spares stoddart c...

Отзывы: