Page 7
Due to continuous product research and development,
the information contained herein is subject to change without notice.
www.stoddart.com.au
www.stoddart.co.nz
Installation
IMPORTANT
DO NOT install unit under a bench.
Under Bench installation will void warranty
Positioning
The room where the equipment will be positioned must:
• Be ventilated and not exposed to atmospheric agents;
• Have a smooth, level floor which can bear the weight of the appliance at full load.
• Have a temperature above +4°C;
• Have maximum humidity of 70%;
• Comply with the regulations in force in terms of safety in the workplace and the systems;
• Not contain potentially explosive materials or substances;
• Be dedicated to food preparation. In addition, a gas-fired appliance requires, by law, rooms with a surface area and ventilation that are
suitable for the power of the oven and that have a means of externally evacuating flue gases
• Please consult national and local standards to ensure that your unit is positioned in accordance with any existing requirements
• Do not allow cables or other items to rest/hang over the exhaust vents
• Heat Source: 500mm clearance from an external heat source is required in order to protect the oven control components. For
clearances under 500mm, it is mandatory for Stoddart heat shields to be fitted while still maintaining a minimum clearance of 50mm
to allow access to the unit. Failure to adhere to minimum clearances may void the oven warranty or add service costs due to lack of
access.
WALL
Hea
t Shield
Hea
t Shield
50mm
500mm
500mm
HEAT
SOURCE
HEAT
SOURCE
OVEN
WALL
50mm
50mm
50mm
HEAT
SOURCE
HEAT
SOURCE
OVEN
WALL
50mm
OVEN
50mm
50mm
NON - HEAT
SOURCE
NON - HEAT
SOURCE
Heat Source
Heat Source With Heat Shield