Page 14
Due to continuous product research and development,
the information contained herein is subject to change without notice.
www.stoddart.com.au
www.stoddart.co.nz
Installation
COLD WATER CONNECTION
WITH ISOLATION VALVE
(EXISTING CONNECTION)
OVEN
WASH
SYSTEM
OVEN
STEAM
GENERATION
A
J
I
I
F
F
D
D
D
H
C
B
E
G
G
Water Connection - BWT Filter
IMPORTANT
This oven must be installed in accordance with AS/NZS 3500.1
The Oven must be installed with the supplied Dual Check Valve,
Water Filter and Pressure Limiting Valves
WASH
SYSTEM
INLET
STEAM
GENERATION
INLET
• Water connections are labelled on the oven
• Isolation valve must be installed at the water
supply outlet
• Water Temperature:
Min 10°C, Max 35°C
• Steam Generation:
The Combi oven requires
filtered water supplied to its steam generation
system. Water pressure must be 300-350 kPa
(43-51 psi) at oven connection. This is controlled
with the supplied PLV
• Wash System:
The Combi oven requires
unfiltered water supplied to its wash system.
Water pressure must be 300-350 kPa (43-51 psi)
at oven connection. This is controlled with the
supplied PLV
• Refer to the BWT user manual for filter setup
Supplied Components
(Plumbing Kit / Water Filter Kit)
A. 1 x BWT Filter
B. 1 x Dual Check Valve
C. 1 x 4 Way Manifold
D. 3 x 3/4” BSP To 3/8” Tube Connector
E. 1 x 1/2” BSP To 3/8” Tube Connector
F. 2 x 3/8” John Guest Stem Elbow
G. 2 x Pressure Limiting Valve
300-350
Kpa
H. 1 x Nipple, 3/4” Male
I. 1 x 3m 3/8 Tube (Water)
J. 12 x John Guest Locking Clip